Evidence map›Paper›PMID 40040305›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2025

High-Speed Hyperspectral Imaging for Near Infrared Fluorescence and Environmental Monitoring.

Jan Stegemann, Franziska Gröniger, Krisztian Neutsch, Han Li, Benjamin Scott Flavel, Justus Tom Metternich, Luise Erpenbeck, Poul Bering Petersen, Per Niklas Hedde, Sebastian Kruss

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. High-Speed Hyperspectral Imaging for Near Infrared Fluorescence and Environmental Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jan StegemannDepartment of Chemistry and Biochemistry, Ruhr University Bochum, 44801, Bochum, Germany.ORCID https://orcid.org/0000-0001-5270-1042
Franziska GrönigerFraunhofer Institute for Microelectronic Circuits and Systems, 47057, Duisburg, Germany.ORCID https://orcid.org/0009-0001-3159-2796
Krisztian NeutschDepartment of Chemistry and Biochemistry, Ruhr University Bochum, 44801, Bochum, Germany.ORCID https://orcid.org/0000-0002-9848-3068
Han LiDepartment of Mechanical and Materials Engineering, University of Turku, Turku, FI-20014, Finland.ORCID https://orcid.org/0000-0002-0597-8409
Benjamin Scott FlavelInstitute of Nanotechnology, Karlsruhe Institute of Technology, 76021, Karlsruhe, Germany.ORCID https://orcid.org/0000-0002-8213-8673
Justus Tom MetternichDepartment of Chemistry and Biochemistry, Ruhr University Bochum, 44801, Bochum, Germany.ORCID https://orcid.org/0000-0001-9233-2739
Luise ErpenbeckDepartment of Dermatology, University Hospital Münster, 48149, Münster, Germany.ORCID https://orcid.org/0000-0002-6561-472X
Poul Bering PetersenDepartment of Chemistry and Biochemistry, Ruhr University Bochum, 44801, Bochum, Germany.ORCID https://orcid.org/0000-0002-9821-700X
Per Niklas HeddeBeckman Laser Institute & Medical Clinic, University of California, Irvine, CA, 92612, USA.ORCID https://orcid.org/0000-0002-2994-369X
Sebastian KrussDepartment of Chemistry and Biochemistry, Ruhr University Bochum, 44801, Bochum, Germany.ORCID https://orcid.org/0000-0003-0638-9822

Funding

Bundesministerium für Bildung und ForschungDeutsche Forschungsgemeinschaft EXC 2033 - 390677874 - RESOLVFraunhofer-Gesellschaft Grant No. Attract 038-610097Ministerium für Kultur und Wissenschaft des Landes Nordrhein-Westfalen Center for Solvation Science ZEMOSVolkswagen Foundation
6 · The paper itself

Abstract

Hyperspectral imaging captures both spectral and spatial information from a sample but is intrinsically slow. The near infrared (NIR, > 800 nm) is advantageous for imaging applications because it falls into the tissue transparency window and also contains vibrational overtone and combination modes useful for molecular fingerprinting. Here, fast hyperspectral NIR imaging is demonstrated using a spectral phasor transformation (HyperNIR). A liquid crystal variable retarder (LCVR) is used for tunable, wavelength-dependent sine- and cosine-filtering that transforms optical signals into a 2D spectral (phasor) space. Spectral information is thus obtained with just three images. The LCVR can be adjusted to cover a spectral range from 900 to 1600 nm in windows tunable from 50 to 700 nm, which enables distinguishing NIR fluorophores with emission peaks less than 5 nm apart. Furthermore, label-free hyperspectral NIR reflectance imaging is demonstrated to identify plastic polymers and monitor in vivo plant health. The approach uses the full camera resolution and reaches hyperspectral frame rates of 0.2 s

Indexed as

fluorescencehyperspectral imaginglabel‐freenear infraredspectral phasor

Identifiers

PMID40040305
PMCPMC12021105

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.