ArticleIEEE transactions on bio-medical engineering2025
Multi-Material Decomposition Using Spectral Diffusion Posterior Sampling.
Article in IEEE transactions on bio-medical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- A Dual-Energy CBCT With Reduced Scatter and Cone Beam Artifacts Using an X-Ray Source Array and Interlaced Spectral Filters.IEEE transactions on bio-medical engineering · 2026Article
- Joint Estimation of Scatter Distribution and Material Maps in Volumetric Dual-Layer Cone-Beam CT.Proceedings of SPIE--the International Society for Optical Engineering · 2026Article
- One-Step Material Decomposition Using Spectral Diffusion Posterior Sampling in Sparse-View Dual-Layer CT.Proceedings of SPIE--the International Society for Optical Engineering · 2026Article
- Joint CT reconstruction of anatomy and implants using a mixed prior model.Journal of medical imaging (Bellingham, Wash.) · 2025Article
- Optimization-based image reconstruction regularized with inter-spectral structural similarity for limited-angle dual-energy cone-beam CT.Physics in medicine and biology · 2025Article
- Joint Reconstruction and Scatter Estimation in Cone-beam CT using Diffusion Posterior Sampling.Proceedings of SPIE--the International Society for Optical Engineering · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
objectiveAccurate material decomposition is critical for many spectral CT applications. In this work, we introduce a novel framework-spectral diffusion posterior sampling (Spectral DPS)-designed for one-step reconstruction and multi-material decomposition.
methodsSpectral DPS combines sophisticated prior information captured by one-time unconditional network training and an arbitrary analytic physical system model. Built upon the general DPS framework for nonlinear inverse problems, Spectral DPS incorporates several DPS strategies from our previous work, including jumpstart sampling, Jacobian approximation, and multi-step likelihood updates. The effectiveness of Spectral DPS was evaluated on a simulated dual-layer and a kV-switching spectral system as well as on a physical cone-beam CT (CBCT) test bench.
resultsIn comparison with other diffusion-based algorithms, Spectral DPS showed significant improvements in reducing sampling variability and computational costs over Baseline DPS. Additionally, Spectral DPS outperformed Conditional Denoising Diffusion Probabilistic Model (DDPM), which was trained on specific imaging conditions, in terms of imaging accuracy and robustness across different imaging protocols. In the physical phantom study, Spectral DPS achieved a $< $1% error in estimating the mean density in a homogeneous region, while effectively avoiding the introduction of false structures seen in Baseline DPS.
conclusionBoth simulation and physical phantom studies demonstrated the superior performance of Spectral DPS on accurate, stable, and fast material decomposition. SIGNIFICANCE: Proposed Spectral DPS provided a novel and general material-decomposition framework which can effectively combine learning-based prior and physics-based spectral model. This method can be applied to various spectral CT systems and basis materials.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.