ArticleMagnetic resonance in medicine2025
3D MERMAID: 3D Multi-shot enhanced recovery motion artifact insensitive diffusion for submillimeter, multi-shell, and SNR-efficient diffusion imaging.
Article in Magnetic resonance in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Phase-Pole-Free Images and Smooth Coil Sensitivity Maps by Regularized Nonlinear Inversion.Magnetic resonance in medicine · 2026Article
- Analysis of cortical dysplasias using b-tensor encoding diffusion MRI in an animal model.PloS one · 2026Article
- 3D MERMAID: 3D Multi-shot enhanced recovery motion artifact insensitive diffusion for submillimeter, multi-shell, and SNR-efficient diffusion imaging.Magnetic resonance in medicine · 2025Article
- Mapping the aggregate g-ratio of white matter tracts using multi-modal MRI.Imaging neuroscience (Cambridge, Mass.) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
purposeTo enhance SNR per unit time of diffusion MRI to enable high spatial resolution and extensive q-sampling in a feasible scan time on clinical scanners.
methods3D multi-shot enhanced recovery motion-insensitive diffusion (MERMAID) consists of a whole brain nonselective 3D multi-shot spin-echo sequence with an inversion pulse immediately before the excitation pulse to enhance the recovery of longitudinal magnetization. The excitation flip angle is reduced to the Ernst angle. The sequence includes a trajectory using radially batched internal navigator echoes (TURBINE) readout, where a 3D projection of the FOV is acquired at a different radial angle in every shot. An image-based phase-correction method combined with compressed sensing image reconstruction was developed to correct phase errors between shots. The performance of the 3D MERMAID sequence was investigated using Bloch simulations as well as phantom and human scans at 3 T and then compared to a typical multi-slice 2D spin-echo sequence.
resultsImprovements in SNR per unit time of 70%-240% were observed in phantom and human scans when using 3D MERMAID compared to a single-slice 2D spin-echo sequence. This SNR per unit time improvement allowed scans to be acquired at a nominal isotropic resolution of 0.74 mm and a total of 112 directions across four shells (b = 150, 300, 1000, 2000 s/mm
conclusionThe 3D MERMAID sequence was shown to significantly improve SNR per unit time compared to multi-slice 2D and 3D diffusion sequences. This SNR improvement allows for shorter scan times and higher spatial and angular resolutions on clinical scanners.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials