Evidence map›Paper›PMID 40034843›Full record

ArticleHardwareX2025

A portable electrical impedance tomography based pressure mapping sensor and force localisation validation system.

Richie Ellingham, Lui Holder-Pearson, Chris Pretty, Tim Giffney

Abstract read
In one paragraph

Article in HardwareX, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Richie EllinghamMechanical and Mechatronic Engineering Department, Canterbury University, Ilam, Christchurch, Canterbury, 8041, New Zealand.
Lui Holder-PearsonElectrical and Electronics Engineering Department, Canterbury University, Ilam, Christchurch, Canterbury, 8041, New Zealand.
Chris PrettyMechanical and Mechatronic Engineering Department, Canterbury University, Ilam, Christchurch, Canterbury, 8041, New Zealand.
Tim GiffneyMechanical and Mechatronic Engineering Department, Canterbury University, Ilam, Christchurch, Canterbury, 8041, New Zealand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This work presents portable, low-cost hardware for pressure mapping using EIT-based soft sensors. An important part of developing these EIT-based pressure sensors is the sensor characterisation. Therefore, this work also provides the design of a system for characterising and validating the spatial, pressure, and temporal performance of different soft sensor material domains. The system is capable of driving soft EIT-based sensors using a range of sensing materials, shapes, and configurations. The hardware allows for the wireless transmission of EIT data to a remote device. A data capture frame rate of 12.7 Hz allows for the analysis of dynamic events. The maximum current drive voltage is ±22 V and a voltage read resolution of

Indexed as

Artificial skinElectrical impedance tomographyPortablePressure mappingResearch and development kitSoft sensor

Identifiers

PMID40034843
PMCPMC11875815

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.