Evidence map›Paper›PMID 40033253›Full record

ArticleBMC medical informatics and decision making2025

Reliability and validity of a novel single-lead portable electrocardiogram device for pregnant women: a comparative study.

Haixue Wang, Jianwei Wang, Wei Jing, Shanshan Dai, Deyun Zhang, Shijia Geng, Haijun Wang, Shenda Hong

Abstract readComparative StudyValidation Study
In one paragraph

Article in BMC medical informatics and decision making, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Haixue Wang *National Institute of Health Data Science, Peking University, Peking University Health Science Center- Weifang Joint Research Center for Maternal and Child Health, Beijing, China.
Jianwei Wang *Weifang Maternal and Child Health Hospital, Peking University Health Science Center-Weifang Joint Research Center for Maternal and Child Health, Weifang, Shandong Province, China.
Wei JingWeifang Maternal and Child Health Hospital, Peking University Health Science Center-Weifang Joint Research Center for Maternal and Child Health, Weifang, Shandong Province, China.
Shanshan DaiWeifang Maternal and Child Health Hospital, Peking University Health Science Center-Weifang Joint Research Center for Maternal and Child Health, Weifang, Shandong Province, China.
Deyun ZhangHeartVoice Medical Technology, Hefei, China.
Shijia GengHeartVoice Medical Technology, Hefei, China.
Haijun WangDepartment of Maternal and Child Health, School of Public Health, Peking University, Peking University Health Science Center-Weifang Joint Research Center for Maternal and Child Health, Beijing, China. whjun1@bjmu.edu.cn.
Shenda HongNational Institute of Health Data Science, Peking University, Beijing, China. hongshenda@pku.edu.cn.

Funding

Beijing Natural Science Foundations QY23040National Natural Science Foundation of China No.62102008
6 · The paper itself

Abstract

backgroundWenXinWuYang, a novel portable Artificial Intelligence Electrocardiogram (AI-ECG) device, can detect many kinds of abnormal heart disease and perform a single-lead ECG, but its reliability and validity among pregnant women is unclear. The aim of this study was to assess the reliability and validity of heart rate, ECG measurements and diagnostic results by compared the portable device with a clinical 12-lead ECG among pregnant women.

methodsWe conducted a clinical study at a municipal-level maternal and child health care hospital. The pregnant women who visited the ECG room for ECG examination were invited to participate in this study. Each participant underwent three ECG recordings: one with conventional 12-lead ECG and two with WenXinWuYang ECG. The first WenXinWuYang ECG was recorded simultaneously with the 12-lead ECG. We collected heart rate, ECG measurements, and diagnostic results related to arrhythmias from both ECG devices. The data were then analyzed using Spearman rank correlation coefficients, consistency analyses, and Bland-Altman plots.

resultsThe study included 287 ECG recordings from 99 pregnant women, with a balanced distribution across different stages of pregnancy. We observed strong to moderate correlations between the two WenXinWuYang measurements for heart rate (r = 0.847), PR interval (r = 0.728), QRS duration (r = 0.636), QT interval (r = 0.836), and QTc interval (r = 0.648), with a diagnostic consistency rate exceeding 90.0%. When compared with the 12-lead ECG, the mean differences for heart rate, PR interval, QRS duration, QT interval, and QTc interval were - 0.4 ± 3.1 bpm (r = 0.957), 14.6 ± 12.4 ms (r = 0.537), 7.0 ± 8.9 ms (r = 0.136), 2.1 ± 12.0 (r = 0.774), and 6.6 ± 16.5 (r = 0.663), respectively. Although the correlation coefficient was low in QRS duration, Bland-Altman results showed moderate to strong agreement between these intervals. Sinus rhythm recognition was fully consistent with the 12-lead ECG, with higher validity in detecting arrhythmias (sensitivity 84.2%, specificity 97.5%). Similar trends existed among different stages of pregnancy.

conclusionWenXinWuYang demonstrated acceptable reliability and validity in measuring heart rate, ECG measurements, and detecting arrhythmias among pregnant women.

Indexed as

Arrhythmias, CardiacArtificial IntelligenceElectrocardiographyAdultFemaleHeart RateHumansPregnancyReproducibility of ResultsYoung Adult12-lead ECGECGPortable deviceReliabilityValidity

Identifiers

PMID40033253
PMCPMC11877860

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.