ArticleIEEE transactions on bio-medical engineering2025
Enhancing Passive Cavitation Imaging Using p
Article in IEEE transactions on bio-medical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Histotripsy-Initiated Immune Response Synergizes with Chemotherapy in a Neuroblastoma Murine Model.Cancers · 2026Article
- Passive cavitation imaging with pMedical physics · 2026Article
- Changes in bubble-cloud dissolution throughout the application of histotripsy pulses.Physical review applied · 2025Article
- Ultrasound-Mediated Membrane Modulation for Biomedical Applications.Nanomaterials (Basel, Switzerland) · 2025Review
- Smart Thrombosis Care: The Rise of Closed-Loop Diagnosis-to-Treatment Nano Systems.International journal of nanomedicine · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
objectivePassive cavitation imaging (PCI) derived metrics can serve as surrogates for the outcome of bubble-mediated therapies. Passive cavitation imaging is limited by poor axial resolution and side lobe artifacts, particularly when algorithms such as delay, sum and integrate (DSI) beamforming are used. Methods to improve PCI performance remain an active research area given the need to balance imaging performance with computational complexity. The current study evaluated p
methodsFirst, PCI was performed on a flow phantom perfused with ultrasound contrast agent (SonoVue) exposed to focused ultrasound. Next, the performance of prDSI was assessed on histotripsy bubble clouds generated in a red blood cell (RBC)-doped phantom. Finally, PCI was performed on data collected during histotripsy ablation of a thrombus in the femoral vein of a pig. Acoustic emissions generated by cavitation were recorded and processed with DSI, robust Capon, and prDSI beamforming. The imaging performance was evaluated using the axial width, signal-to-interference ratio, and binary statistical analysis-derived metrics.
resultsThe prDSI approach demonstrated comparable imaging performance to RCB, both in vitro and in vivo based on binary statistical metrics. Considerable improvement was observed in axial width and signal-to-interference ratio, while incurring only a moderately higher computational cost relative to standard DSI beamforming.
conclusionsThe findings of this study demonstrate the potential of prDSI for monitoring of cavitation-mediated therapies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.