ArticleIEEE transactions on bio-medical engineering2025
Human-in-the-Loop Optimization of Hip Exoskeleton Assistance During Stair Climbing.
Article in IEEE transactions on bio-medical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Optimization of Exoskeleton Assistance Function Based on Physics-Guided Dynamic Fusion Model.Bioengineering (Basel, Switzerland) · 2026Article
- A soft hip exoskeleton biomimetic assistance method incorporating dual‑pretension and biomechanics‑based force modeling.Medical & biological engineering & computing · 2026Article
- Article
- A Soft Exoskeleton for Hand Grip Augmentation and Fall Prevention Assistance in Tower Climbing.Biomimetics (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
objectiveThis study applies human-in-the-loop optimization to identify optimal hip exoskeleton assistance patterns for stair climbing.
methodsTen participants underwent optimization to individualize hip flexion and extension assistance, followed by a validation comparing optimized assistance (OPT) to biological hip moment-based assistance (BIO), no assistance (No-Assist), and no exoskeleton (No-Exo) conditions.
resultsOPT reduced metabolic cost by 4.5% compared to No-Exo, 11.44% compared to No-Assist, and 5.02% compared to BIO, demonstrating the effectiveness of the optimization approach. Statistical analysis revealed distinct characteristics in optimal assistance timing and magnitude that deviated systematically from biological hip moment patterns. Compared to BIO, OPT exhibited later peak flexion timing (76.4 $\pm$ 3.7% vs 65.0%), shorter flexion duration (29.2 $\pm$ 3.6% vs 40.0%), later peak extension timing (26.7 $\pm$ 3.8% vs 20.0% of gait cycle), and higher peak flexion magnitude (11.1 $\pm$ 1.5 Nm vs 10.0 Nm). While individual optimal assistance profiles varied across participants, comparison between individually optimized parameters and the best subject-independent parameters identified through post-hoc analysis showed consistency. On average, metabolic rate convergence was achieved after 18 iterations, while most exoskeleton control parameters did not reach our convergence criteria within 20 iterations.
conclusionThese findings demonstrate that human-in-the-loop optimization can effectively identify task-specific assistance patterns for stair climbing, while the consistency between individual and subject-independent parameters suggests the potential for developing generalized assistance strategies. The systematic differences between optimized and biological moment-based assistance underscore the fundamental distinctions between biological torque-based control and optimal control for exoskeleton assistance.