ArticleEuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology2025
Outcomes of tricuspid transcatheter edge-to-edge repair in subjects with endocardial leads.
Article in EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Beyond multivalvular disease: imaging-guided diagnosis and management of combined functional mitral and tricuspid regurgitation.European heart journal. Imaging methods and practice · 2025Article
- Patient Phenotypes Undergoing Tricuspid Transcatheter Edge-to-Edge Repair: Finding the Optimal Candidate.Journal of cardiovascular development and disease · 2025Review
- CIED and tricuspid regurgitation - a LEADing problem?EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTranscatheter edge-to-edge repair (TEER) using the TriClip tricuspid valve repair system has emerged as a therapy for tricuspid regurgitation (TR). Patients with TR undergoing TEER commonly present with an endocardial lead across the tricuspid valve (TV).
aimsWe sought to examine the effectiveness and safety of tricuspid TEER (T-TEER) in subjects with endocardial leads in the bRIGHT EU Post-Approval Study (PAS).
methodsThe bRIGHT EU PAS is a prospective, single-arm, open-label, multicentre, post-market registry conducted at 26 sites in Europe. Echocardiographic assessments of endocardial lead placement, interaction, and TR grade were performed at a core laboratory.
resultsOf the 511 enrolled subjects, a total of 110 had an endocardial lead, and in 80.7% of these subjects, TR was at least partially related to the lead. At 30 days, 71% of subjects with endocardial leads had TR of moderate or less. The percentage of subjects with endocardial leads categorised as New York Heart Association Functional Class I-II increased from 17% at baseline to 75% at 30 days (p<0.0001), and quality of life with the Kansas City Cardiomyopathy Questionnaire showed a mean improvement of 20±24 points from baseline to 30 days (p<0.0001). T-TEER was safe in subjects with endocardial leads, with similar rates of events, including TV reintervention/reoperation and TV surgery, to those in subjects without leads. No reports of lead malfunction were reported.
conclusionsIn the bRIGHT EU PAS, T-TEER using the TriClip system was safe and effective in severe TR subjects with an endocardial lead across the TV.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.