In one paragraph

Article in Heliyon, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Jennifer M TurnerCardiff University, School of Optometry and Vision Sciences, Maindy Road, Cardiff, CF24 4HQ, UK.
Chi Hieu LeUniversity of Greenwich, School of Engineering, Central Avenue, Medway, ME4 4TB, UK.
Paul J MurphyUniversity of Waterloo, School of Optometry and Vision Science, University Avenue West, Waterloo, N2L 3G1, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To develop a method for accurate 3-dimensional (3D) representation of the anterior ocular surface (AOS) based on ocular impression and reverse engineering of an AOS plaster biomodel. Methods: An AOS plaster biomodel was fabricated using ocular impression and a developed casting support device (CSD) and landmark registration element (LRE) to stabilise and consistently fix the impression casting tray within the casting support during the casting process. The touch-trigger probe on a co-ordinate measurement machine (CMM) digitised the AOS plaster biomodel to represent the AOS shape. The CSD and LRE were manufactured using an Additive Manufacturing selective laser sintering (SLS) process. A single stainless-steel ball (diameter: 22 mm) was cast as a surrogate AOS biomodel using polyvinylsiloxane impression material. The surrogate biomodel which was used to evaluate material selection and stability of the AOS biomodels fabricated using the CSD and LRE, and to evaluate repeatability and reproducibility of the point cloud data collection methods. The points of circular profiles were measured at different Z values in mm: z = -1 mm, z = -2 mm, z = - 3 mm, z = -4 mm and z = -5 mm. Results: The measurements were highly repeatable with an acceptable tolerance. For the typical case of the surrogate AOS biomodel, the average distance of the digitised points to the best-fit sphere of all the digitised points from four measurements ranges from 0.002 to 0.010 mm. The shrinkage study of the surrogate AOS biomodels was conducted, with measurements taken one month apart for comparison. The analysis results showed that most of the surrogate AOS biomodels reduced in size but within an acceptable tolerance, in which the mean error is from 0.005 to 0.010 mm for the 2D circular profiles measured at Z = -4 mm. Conclusions: The Cardiff Eye Shape Analysis Protocol (CESAP) provides a repeatable and consistent method for producing solid, white-plaster, representations of a plaster cast AOS biomodel. Casting an impression in white plaster (Novadur™) produces a consistent surrogate AOS biomodel of a single stainless-steel 22 mm diameter ball. CESAP can be used as a framework for consistently converting an ocular impression into a 'real' AOS model that can be reverse-engineered to create 3D CAD models of the AOS shape for potential applications in optical image (topographer) calibration, prosthetic shell and scleral lens design, and AOS database development.

Indexed as

Corneal topographyImpression mouldingLaser scanningOcular surface shapeScleral lens

Identifiers

PMID40028595
PMCPMC11870247

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials