Evidence map›Paper›PMID 40027429›Full record

ArticleIEEE sensors letters2025

A Simple Circuit for Time-Resolved Luminescence (TRL) Measurement Instruments: Demonstration Through a Smartphone-Based TRL Imager for Anticounterfeiting Application.

Alim Gulbag, Michael Huang, Brian Rong, Benjamin Sreenan, Xiaoshan Zhu

Abstract read
In one paragraph

Article in IEEE sensors letters, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Alim GulbagDepartment of Electrical and Biomedical Engineering, University of Nevada Reno, NV 98557 USA.
Michael HuangDepartment of Electrical and Biomedical Engineering, University of Nevada Reno, NV 98557 USA.
Brian RongDepartment of Electrical and Biomedical Engineering, University of Nevada Reno, NV 98557 USA.
Benjamin SreenanDepartment of Electrical and Biomedical Engineering, University of Nevada Reno, NV 98557 USA.
Xiaoshan ZhuDepartment of Electrical and Biomedical Engineering, University of Nevada Reno, NV 98557 USA.

Funding

Time-Gated Fluorescence Lateral Flow Immunoassay for Melioidosis DiagnosisR15GM135855 · NIGMS · UNIVERSITY OF NEVADA RENO · PI ZHU, XIAOSHAN · 2020 to 2020
$426k
NIGMS NIH HHS R15 GM135855
6 · The paper itself

Abstract

Time-resolved luminescence (TRL) measurement is a sensitive detection technique by eliminating sample autofluorescence, but TRL measurement instruments composed of multiple key components (e.g., a rapidly pulsed light excitation source, a time-gated optical detector, and a synchronization module aligning the timing between the light source and the detector) have been sophisticated, expensive, or bulky, which limits their point-of-care or in-field applications. To reduce the cost and complexity of these instruments, in this work, we developed a simple circuit for rapid LED pulsing and accurate timing synchronization, and implemented it in a compact TRL imager with a UV LED as light source and a chopper-coupled smartphone camera as time-gated optical detector. The TRL measurement of this imager using this circuit was successfully validated through an anticounterfeiting application. We believe that this simple circuit can be adopted in the development of low-cost and compact TRL measurement instruments for broad point-of-care or in-field applications.

Indexed as

anticounterfeitingoptical choppersmartphonesynchronizationTime-resolved luminescence

Identifiers

PMID40027429
PMCPMC11870667

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.