Investigation of 2D anti-scatter grid implementation in a gantry-mounted cone beam computed tomography system for proton therapy.

Uttam Pyakurel, Yawei Zhang, Ryan Sabounchi, Farhang Bayat, Sébastien Brousmiche, Curtis Bryant, Nancy Mendenhall, Perry Johnson, Cem Altunbas

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Uttam PyakurelDepartment of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail stop F-706, Aurora, CO 80045, USA.
Yawei ZhangUniversity of Florida Health Proton Therapy Institute, 2015 N Jefferson St, Jacksonville, FL 32206, USA.
Ryan SabounchiDepartment of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail stop F-706, Aurora, CO 80045, USA.
Farhang BayatDepartment of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail stop F-706, Aurora, CO 80045, USA.
Sébastien BrousmicheIon Beam Applications, 3 Chemin du Cyclotron, 1348 Louvain-la-Neuve, Belgium.
Curtis BryantUniversity of Florida Health Proton Therapy Institute, 2015 N Jefferson St, Jacksonville, FL 32206, USA.
Nancy MendenhallUniversity of Florida Health Proton Therapy Institute, 2015 N Jefferson St, Jacksonville, FL 32206, USA.
Perry JohnsonUniversity of Florida Health Proton Therapy Institute, 2015 N Jefferson St, Jacksonville, FL 32206, USA.
Cem AltunbasDepartment of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail stop F-706, Aurora, CO 80045, USA.

Funding

Improving quantitative accuracy and tissue visualization in CBCT guided radiation therapyR01CA245270 · NCI · UNIVERSITY OF COLORADO DENVER · PI ALTUNBAS, CEM · 2020 to 2025
$2.1M
NCI NIH HHS R01 CA245270
6 · The paper itself

Abstract

Background and purpose: Robust scatter mitigation by 2D anti-scatter grids (2D-ASG) in proton therapy cone beam computed tomography (CBCT) may improve target visualization and computed tomography (CT) number fidelity, allowing online dose verifications and plan adaptations. However, grid artifact-free implementation of 2D-ASG depends on the CBCT system characteristics. Thus, we investigated the feasibility of 2D-ASG implementation in a proton therapy gantry-mounted CBCT system and evaluated its impact on image quality. Materials and methods: A prototype 2D-ASG and a grid support platform were developed for a proton therapy CBCT system with a 340 cm source to imager distance. The effect of gantry flex on 2D-ASG's wall shadows and scan-to-scan reproducibility of 2D-ASG's wall shadows were evaluated. Experiments were conducted to assess 2D-ASG's wall shadow suppression and the effect of 2D-ASG on image quality. Results: While maximum displacement in 2D-ASG wall shadows was 103 µm during gantry rotation, the drift from baseline over 3 months was 8 µm and 1 µm in the transverse and axial directions. 2D-ASG shadows were successfully suppressed in CBCT images. With 2D-ASG, maximum Hounsfield Unit (HU) nonuniformity decreased from 134 to 45 HU, contrast-to-noise ratio (CNR) increased by a factor of 2.5, and HU errors were reduced from 34 % to 5 %. Conclusions: Proton therapy gantry flex was highly reproducible and did not noticeably affect 2D-ASG wall shadow suppression in CBCT images, supporting its feasibility in proton therapy CBCT system. Improved CT accuracy and artifact reduction with 2D-ASG could enhance CBCT-based proton therapy dose calculations.

Indexed as

2D anti-scatter gridProton gantry CBCTProton gantry flexScatter mitigation