Evidence map›Paper›PMID 40026906›Full record

ArticlePhysics and imaging in radiation oncology2025

Margins to compensate for respiratory-induced mismatches between lung tumor and fiducial marker positions using four-dimensional computed tomography.

Seiya Matsumoto, Nobutaka Mukumoto, Tomohiro Ono, Hiraku Iramina, Hideaki Hirashima, Takanori Adachi, Yuki Miyabe, Noriko Kishi, Takashi Mizowaki, Mitsuhiro Nakamura

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Seiya MatsumotoDepartment of Advanced Medical Physics, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 Japan.
Nobutaka MukumotoDepartment of Radiation Oncology, Graduate School of Medicine, Osaka Metropolitan University, 1-5-7 Asahi-machi, Abeno-ku, Osaka 545-0051 Japan.
Tomohiro OnoDepartment of Radiation Oncology, Shiga General Hospital, 5-4-30 Moriyama, Moriyama, Shiga 524-0022, Japan.
Hiraku IraminaDepartment of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
Hideaki HirashimaDepartment of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
Takanori AdachiDepartment of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
Yuki MiyabeDepartment of Radiation Oncology, Kitano Hospital, 2-4-20 Ogi-machi, Kita-ku, Osaka 530-8480, Japan.
Noriko KishiDepartment of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
Takashi MizowakiDepartment of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
Mitsuhiro NakamuraDepartment of Advanced Medical Physics, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: Tumors and fiducial markers do not always exhibit synchronous motion across different respiratory phases, in a phenomenon called the target localization error (TLE). We determined the margin to compensate for the TLE using four-dimensional computed tomography (4D-CT). Materials and methods: We analyzed data from 21 lung tumor patients with fiducial markers; 11 for TLE determination and 10 for validation. Shifted CT images were generated by aligning the centroids of the fiducial markers in the reference phase of 4D-CT with those in each respiratory phase, and the union of gross tumor volumes (GTVs) was determined ( Results: The TLEs (standard deviations of the root mean square error) were 2.0 (0.8) mm, 2.1(0.7) mm, and 3.2 (1.1) mm in the left - right, anterior - posterior, and superior - inferior directions, respectively. A dosimetric evaluation revealed that Conclusion: The TLE can be compensated by adding an anisotropic margin to the GTV in the reference phase, a critical consideration in DTT.

Indexed as

Fiducial markersFour-dimensional computed tomographyLungStereotactic body radiotherapyTarget localization error

Identifiers

PMID40026906
PMCPMC11871501

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.