Evidence map›Paper›PMID 40026896›Full record

ArticleBiomedical engineering letters2025

Enhanced model antigen retention in tissue through topical high-frequency ultrasound treatment.

Dasom Heo, Hyunhee Kim, Wataru Katagiri, Changhan Yoon, Hae Gyun Lim, Chulhong Kim, Hak Soo Choi, Satoshi Kashiwagi, Hyung Ham Kim

Abstract read
In one paragraph

Article in Biomedical engineering letters, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Dasom Heo *Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, 37673 Republic of Korea.ORCID 0000-0003-0482-6822
Hyunhee KimDepartment of Convergence IT Engineering, Pohang University of Science and Technology (POSTECH), Pohang, 37673 Republic of Korea.ORCID 0000-0003-3241-3638
Wataru KatagiriGordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, 149 13th Street, Boston, MA 02129 USA.
Changhan YoonDepartment of Biomedical Engineering, Inje University, Gimhae, 50834 Republic of Korea.ORCID 0000-0002-6573-2582
Hae Gyun LimDepartment of Biomedical Engineering, Pukyong National University, Busan, 48513 Republic of Korea.ORCID 0000-0002-4182-7130
Chulhong KimDepartment of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, 37673 Republic of Korea.ORCID 0000-0001-7249-1257
Hak Soo ChoiGordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, 149 13th Street, Boston, MA 02129 USA.ORCID 0000-0002-7982-6483
Satoshi KashiwagiGordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, 149 13th Street, Boston, MA 02129 USA.ORCID 0000-0001-8910-3257
Hyung Ham KimDepartment of Convergence IT Engineering, Pohang University of Science and Technology (POSTECH), Pohang, 37673 Republic of Korea.ORCID 0000-0002-6353-5550

Funding

Targeting parathyroid glands with novel fluorophores for intraoperative imagingR01CA280968 · NCI · MASSACHUSETTS GENERAL HOSPITAL · PI Michael Bouvet, Maged M Henary · 2023 to 2026
$2.8M
Long-Acting, Short-Residing Nanochelators for Iron Overload TherapyR01HL163273 · NHLBI · MASSACHUSETTS GENERAL HOSPITAL · PI CHOI, HAK SOO, KIM, JONGHAN · 2023 to 2025
$2.2M
NCI NIH HHS R01 CA280968NHLBI NIH HHS R01 HL163273
6 · The paper itself

Abstract

Reproducible control of tissue delivery and retention of a therapeutic agent facilitates the maximization of the efficacy of pharmacotherapy. Despite the proposal of various chemical and physical methods for modulating drug delivery and retention, the choice of the physical modality for this purpose has been limited in clinical practice. Thus, this study proposes a novel strategy for modulating the retention of a model antigen in tissues by using non-tissue-damaging high-frequency ultrasoundAfter the injection of a fluorescently labeled model antigen, followed by brief treatment with high-frequency ultrasound (5-20 MHz), the clearance of the antigen was monitored using a real-time near-infrared (NIR) fluorescence imaging system in vivo. Further, ultrasound treatment increased tissue retention at the site of model antigen administration. The results suggested that high-frequency ultrasound could change the response to a macromolecule injected into the tissue, such as a vaccine, thereby modulating the immune response. The proposed ultrasound-based technology is translatable to clinical settings and benefits from well-established ultrasound technologies that have been employed in various medical applications for decades. Moreover, this approach can be broadly applied to enhance the therapeutic effects of current and future immune-mediated therapeutic systems.

Indexed as

Drug retentionHigh-frequency ultrasoundNear-infrared imagingZwitterionic fluorophore

Identifiers

PMID40026896
PMCPMC11871201

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.