ArticleBiomedical engineering letters2025
A novel controllable energy constraints-variational mode decomposition denoising algorithm.
Article in Biomedical engineering letters, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Hybrid DWT NLM method with NOA optimization for ECG signal denoising.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Electrocardiogram (ECG) is mainly utilized for diagnosing heart diseases. However, various noises can influence the diagnostic accuracy. This paper presents a novel algorithm for denoising ECG signals by employing the Controlled Energy Constraint-Variational Mode Decomposition (CEC-VMD). Firstly, the noisy ECG signal is decomposed using CEC-VMD to obtain a set of intrinsic mode functions (IMFs) and a residual r. A modulation factor is utilized to minimize the modal information contained in the decomposed residuals. Furthermore, this paper presents an update formula for the modal and central frequencies based on ADMM. Finally, all the IMFs are integrated to obtain the ECG signal after denoising. By varying the value of the modulation factor, not only is the spectral energy loss of each mode reduced, but the orthogonality between the modes is also improved to better concentrate the energy of each mode. The experiments on simulated signals and MIT-BIH signals show that the average SNR after CEC-VMD denoising is 22.5139, the RMSE is 0.1128, and the CC is 0.9882. In addition, the proposed algorithm effectively improves the classification accuracy values, which are 99.0% and 99.9% for the SVM and KNN classifiers, respectively. These values are improved compared with those of EMD, VMD, SWT, SVD-VMD, and VMD-SWT. The proposed CEC-VMD technique for denoising ECG signals removes noise and better preserves features.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.