Evidence map›Paper›PMID 40025683›Full record

ArticleClinical and experimental dental research2025

Evaluation of the Effect of Distance Between Dental Abutments on the Accuracy of One-Step and Two-Step Impression Techniques With Polyvinyl Siloxane (PVS) Material.

Seyyed Ahmad Ghoraishian, Mohsen Khataminia, Zahra Shahramian, Maryam Zare, Mina Mohaghegh

Abstract read
In one paragraph

Article in Clinical and experimental dental research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Seyyed Ahmad GhoraishianDepartment of Prosthodontics, Shiraz University of Medical Sciences, Shiraz Dental School, Shiraz, Iran.
Mohsen KhataminiaDepartment of Prosthodontics, Shiraz University of Medical Sciences, Shiraz Dental School, Shiraz, Iran.ORCID 0009-0002-5959-4344
Zahra ShahramianShiraz University of Medical Sciences, Shiraz Dental School, Shiraz, Iran.
Maryam ZarePrivate Dentist, Shiraz, Iran.
Mina MohagheghDepartment of Prosthodontics, Shiraz University of Medical Sciences, Shiraz Dental School, Shiraz, Iran.ORCID 0000-0002-8751-5255

Funding

This study was supported by the Shiraz University of Medical Sciences.
6 · The paper itself

Abstract

objectiveThe aim of this study was to evaluate the effect of distance between dental abutments on the accuracy of one-step and two-step impression techniques with polyvinyl siloxane (PVS) material. MATERIALS AND

methodsFour master models were fabricated with different interabutment distances equal to one, two, three, and four premolar lengths 1-4 (L1, L2, L3, and L4). Seven one-step impressions were taken from each master model using PVS impression material (Group A, n = 7). For two-step impressions, a 1.5 mm polyethylene spacer was used over each master model, and impressions were taken (Group B, n = 7). Scans from the casts were superimposed over the master model scans. Accordingly, differences were measured and compared with statistical tests (Kolmogorov-Smirnoff test, Mann-Whitney test, and Friedman's test) to evaluate the effect of interabutment distance within each impression technique group and also compare the one-step and two-step impression techniques. p value < 0.05 was considered statistically significant.

resultsA statistically significant difference was noted among the different edentulous areas in the one-step impression technique group (Group A, p = 0.010). At edentulous span, a statistically significant difference was recorded (p = 0.047) with two-step impression technique being more accurate compared to the one-step impression technique. Friedman's pairwise analysis in Group A demonstrated a significance between one premolar and four premolar interabutment distance groups (p = 0.006).

conclusionThe accuracy of the one-step impression is significantly affected by the increase in interabutment distance from one premolar to four premolar edentulous.

Indexed as

Dental AbutmentsDental Impression MaterialsDental Impression TechniquePolyvinylsSiloxanesBicuspidHumansModels, DentalDental Impression MaterialsPolyvinylsSiloxanesvinyl polysiloxaneinterabutment distanceone‐step impressionPVS materialtwo‐step impression

Identifiers

PMID40025683
PMCPMC11872798

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.