Evidence map›Paper›PMID 40025308›Full record

SynthesisArchives of orthopaedic and trauma surgery2025

Clinical added value of 3D printed patient-specific guides in orthopedic surgery (excluding knee arthroplasty): a systematic review.

Nick Kampkuiper, Romy Ten Heggeler, Jorm Nellensteijn, Marjolein Brusse-Keizer, Gabriëlle Tuijthof, Maaike Koenrades, Femke Schröder

Abstract readSystematic Review
In one paragraph

Synthesis in Archives of orthopaedic and trauma surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Experience with patient-specific guides, insteatientad of general surgical experience, improves the accuracy of 3D-guided corrective osteotomies.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
    Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Nick KampkuiperDepartment of Biomechanical Engineering, University of Twente, Enschede, Netherlands. n.f.b.kampkuiper@utwente.nl.
Romy Ten HeggelerMedical 3D Lab, Medisch Spectrum Twente, Enschede, Netherlands.
Jorm NellensteijnDepartment of Orthopedic Surgery, Medisch Spectrum Twente, Enschede, Netherlands.
Marjolein Brusse-KeizerMedical School Twente, Medisch Spectrum Twente, Enschede, Netherlands.
Gabriëlle TuijthofDepartment of Biomechanical Engineering, University of Twente, Enschede, Netherlands.
Maaike KoenradesMedical 3D Lab, Medisch Spectrum Twente, Enschede, Netherlands.
Femke SchröderDepartment of Biomechanical Engineering, University of Twente, Enschede, Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionPatient-specific guides (PSGs) provide customized solutions and enhanced precision. However, the question remains: does clinical evidence support the added value of PSGs? This study critically appraises, summarizes, and compares the literature to assess the clinical value of PSGs in orthopedic surgery. MATERIALS AND

methodsPubMed and Embase were used to search for studies reporting on randomized controlled trials (RCTs) that compared the use of PSGs with a control group for an orthopedic intervention, excluding knee arthroplasty. The risk of bias was assessed using the Cochrane risk-of-bias tool (RoB 2). The clinical value was expressed as patient reported outcome measures (PROMs), complications, accuracy, surgery duration, blood loss, and radiation exposure. Relative and absolute differences were determined, and whether these were negative or positive for using PSGs.

resultsFrom 6310 studies, 27 RCTs were included, covering various interventions. The studies' heterogeneity prevented meta-analysis. Six (22.2%) of the included articles scored low risk of bias. Significant differences in the benefit of PSGs were reported across all included metrics: 32.2% in PROMs, 22.7% in complications, 69.8% in accuracy, 42.1% in surgery duration, 46.7% in blood loss, and 93.3% in radiation exposure. No significant negative differences were found in any of the studies.

conclusionPSGs generally show superior outcomes for accuracy and radiation exposure across multiple intervention types, while the reduction in complications was primarily significant in spinal fusion surgery. For PROMs, complications in other treatments, surgery duration, and blood loss, there may be clinical added value but future well-designed RCTs are needed to provide stronger evidence.

Indexed as

Orthopedic ProceduresPrinting, Three-DimensionalHumansPatient Reported Outcome MeasuresRandomized Controlled Trials as Topic3D3D printingClinical added valueClinical outcomeOrthopedic surgeryPatient-specificRCTSurgical planningSystematic reviewThree-dimensional

Identifiers

PMID40025308
PMCPMC11872977

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.