Evidence map›Paper›PMID 40017730›Full record

ArticleFrontiers in neurology2024

Incorporation of robotic automated transcranial Doppler to screen for patent foramen ovale (PFO) and quantify right-to-left shunt severity in the evaluation of ischemic stroke patients for etiology and PFO management.

Ira Chang, Yasaman Pirahanchi, Simon Izaguirre, Richard Rodriguez, Alyssa Wicknick

Abstract read
In one paragraph

Article in Frontiers in neurology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ira ChangSwedish Medical Center, Englewood, CO, United States.
Yasaman PirahanchiSwedish Medical Center, Englewood, CO, United States.
Simon IzaguirreSwedish Medical Center, Englewood, CO, United States.
Richard RodriguezSwedish Medical Center, Englewood, CO, United States.
Alyssa WicknickSwedish Medical Center, Englewood, CO, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Right-to-left shunt (RLS) associated with patent foramen ovale (PFO) is common among cryptogenic strokes. Current diagnostic tools have limitations. Transthoratic echocardiography (TTE) is not as sensitive as Transesophageal echocardiography (TEE), TEE is invasive, and manual transcranial Doppler (TCD) requires trained staff to operate. Robotic automated TCD (raTCD) may be feasible and comparable to manual TCD. The study's purpose was to determine the rate of RLS detection using raTCD and combine the Spencer Logarithmic Scale (SLS) with the Risk of Paradoxical Embolism (RoPE) to identify patients at risk of PFO associated stroke or TIA. Methods: This single-center retrospective cohort study included adult patients (≥18 y/o) admitted from December 2021 to December 2022 with a stroke or transient ischemic attack. Those with no bone window or stroke mimics were excluded. Patients with an RLS on raTCD received a second scan at the physician's discretion. The SLS combined with the RoPE score was used to generate a modified screening PFO-Associated Stroke Causal Likelihood (msPASCAL) classification. Results: Of 212 patients who received raTCD, the mean age was 56, 14% were >65 years old, most were white (72%), predominantly male (59%), 52% had cryptogenic strokes, and 59% had an RLS. Most patients were able to perform Valsalva (89%) during raTCD. Of those with an RLS, 56% had an SLS of 1-2, while 44% had an SLS of 3-5. There were no significant differences in characteristics by SLS. Most patients with SLS grades 1-2 were classified using msPASCAL as unlikely to have PFO as stroke etiology ( Discussion: This study supports the feasibility of utilizing raTCD for RLS detection. The modified screening PASCAL classification can be generated for RLS patients and may be used to guide subsequent evaluation and management.

Indexed as

ischemic strokepatent foramen ovaleright to left shuntrobotic automated transcranial Dopplertransesophageal echocardiographytransthoracic echocardiography

Identifiers

PMID40017730
PMCPMC11866324

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.