ArticleJournal of experimental orthopaedics2025

Reduced polyethylene wear in dual mobility versus single mobility hip implants: Results from quantitative and qualitative scanning electron microscopy analysis.

Antonio Pompilio Gigante, Marco Senarighi, Carlo Ciccullo, Luca De Berardinis, Luca Farinelli

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Antonio Pompilio GiganteClinical Orthopedics, Department of Clinical and Molecular Sciences, School of Medicine Università Politecnica delle Marche Ancona AN Italy.
Marco SenarighiClinical Orthopedics, Department of Clinical and Molecular Sciences, School of Medicine Università Politecnica delle Marche Ancona AN Italy.ORCID 0009-0006-3508-7187
Carlo CicculloClinical Orthopedics, Department of Clinical and Molecular Sciences, School of Medicine Università Politecnica delle Marche Ancona AN Italy.
Luca De BerardinisClinical Orthopedics, Department of Clinical and Molecular Sciences, School of Medicine Università Politecnica delle Marche Ancona AN Italy.ORCID 0000-0002-9476-4508
Luca FarinelliClinical Orthopedics, Department of Clinical and Molecular Sciences, School of Medicine Università Politecnica delle Marche Ancona AN Italy.ORCID 0000-0003-3048-7764

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Dual mobility cup in total hip arthroplasties has gained popularity worldwide as it reduces instability providing greater range of motion. However, increased polyethylene wear remains debated. This in vitro study aimed to measure and qualitatively analyse the wear of ultra-high molecular weight polyethylene in contemporary dual mobility cup compared to conventional single mobility acetabular component. Methods: Hip simulator was used to compare ultra-high molecular weight polyethylene wear in dual mobility and single mobility acetabular component The specimens were tested at an in vitro angle of 30° relative to the ISO standard fixated position. Flexion/extension, abduction/adduction, and internal/external rotation were simulated. Testing was stopped every 0.5 million cycles until 5.0 million cycles were reached and the liners were disassembled and weighted to assess mass loss. The test fluid was sent for scanning electron microscopy analysis and wear particles were characterized for mean equivalent circle diameter, form factor, maximum Feret diameter, minimum Feret diameter, area, perimeter and aspect ratio. Results: Dual mobility hip reported a lower wear respect to single mobility (20.4 and 39.6 mg/Mcy, Conclusion: Dual mobility cup produces less wear than conventional single mobility acetabular component ensuring lower risk of instability and greater range of motion. Further studies are needed to definitively clarify the issue of wear in the dual mobility prosthesis.

Indexed as

dual mobility cuppolyethylene mobile componenttotal hip arthroplastyultra‐high molecular weight polyethylenewear

Identifiers

PMID40017700
PMCPMC11865326

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.