ArticleActa oncologica (Stockholm, Sweden)2025
Self-measured leg circumference for the detection of lymphedema among men with prostate cancer: a reliability study.
Article in Acta oncologica (Stockholm, Sweden), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeEarly lymphedema detection is crucial to timely treatment, and home-based monitoring holds promise for early detection of leg lymphedema among at-risk cancer survivors. We developed a self-measurement protocol for home-based leg circumference measurements and tested its reliability in men with prostate cancer at risk of lymphedema. PATIENTS/MATERIAL AND
methodsThis cross-sectional study recruited men with prostate cancer from the Department of Urology, Copenhagen University Hospital, Denmark. Circumference measurements were taken at four points on both legs, from which leg volume was calculated. Intrarater reliability was assessed by comparing self-measurements taken at home and in the hospital. Interrater reliability was evaluated by comparing hospital self-measurements to those of a blinded physiotherapist. Statistical power required 13 participants for the detection of a good (>0.8) intraclass correlation coefficient (ICC).
resultsForty-three men were included (median age 69 [63-76] years). Intrarater reliability (n = 39) was good to excellent for six out of eight measurement points (ICC ≥ 0.79, p < 0.01) and moderate for two (ICC ≥ 0.55, p < 0.01). Intrarater reliability for leg volume was excellent (ICC ≥ 0.96, p < 0.01). Similarly, interrater reliability (n = 23) was excellent for all measurement points and leg volumes (ICC ≥ 0.91, p < 0.01). Forty-one of 43 participants performed the measurements independently, found them easy to do, and were willing to conduct self-measurements if recommended by their doctor.
interpretationSelf-measured leg circumference among men with prostate cancer is highly reliable and acceptable. This low-cost approach for home-based monitoring for lymphedema offers potential for early detection and timely management of the condition.
Indexed as