Evidence map›Paper›PMID 40013597›Full record

ArticleThe international journal of medical robotics + computer assisted surgery : MRCAS2025

Automated Digital Image Optimisation in Intraoperative 2D and 3D Imaging Using a Mobile C-Arm With Flat-Panel Detector.

J Groh, M Perl, L Bräuer, H Stadthalter

Abstract read
In one paragraph

Article in The international journal of medical robotics + computer assisted surgery : MRCAS, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

J GrohDepartment of Trauma and Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsklinikum Erlangen, Erlangen, Germany.
M PerlDepartment of Trauma and Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsklinikum Erlangen, Erlangen, Germany.
L BräuerInstitute for Functional and Clinical Anatomy, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
H StadthalterDepartment of Trauma and Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsklinikum Erlangen, Erlangen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAssistance tools for intraoperative 2D and 3D imaging to decrease acquisition effort and to improve assessment of 3D image data were evaluated.

methodsTwo automated optimisation procedures were evaluated in a cadaver (Cios Spin, Siemens, Germany): The ScrewScout function for assisted pedicle screw assessment. Then, an algorithm for metal artefact reduction (MAR). Additionally, a tool for simplified setting of image contrast and brightness was evaluated regarding the result and elapsed time.

resultsThe time required without automated assistance was 83s [70-105]. With the computer assistance, this time was significantly lower at 22s [15-32] (p = 0.003). MAR resulted in an improvement in image impression. This improvement became smaller with increasing clinical experience. The time needed for setting of image acquisition parameters was significantly (p = 0.05) lowered from 140s [24-389] to 61s [14-166] using the assistance tool.

conclusionsAutomated assistance tools for image optimisation can provide practical support in the intraoperative setting.

Indexed as

Image Processing, Computer-AssistedImaging, Three-DimensionalRobotic Surgical ProceduresSurgery, Computer-AssistedAlgorithmsArtifactsCadaverHumansPedicle Screwsautomated image analysisintraoperative imagingMARmetal artifact reductionScrewScoutSpotAdapt

Identifiers

PMID40013597
PMCPMC11866468

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.