ArticleNMR in biomedicine2025
Magnetic Resonance Elastography of Upper Trapezius Muscle.
Article in NMR in biomedicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
The goal of the present study was to investigate the effect of positioning a soft flexible tube-based actuator parallel or orthogonal to the principle muscle fibre direction, on measurements of the stiffness of upper trapezius (UT) muscle obtained using magnetic resonance elastography (MRE). The effects of using three different vibration frequencies (60 Hz, 80 Hz and 100 Hz) and studying left and right sides of the body were also investigated. The relevant MRE datasets were acquired on a 1.5 T MRI system using a 2D gradient-echo (GRE) MRE sequence, and corresponding wave images produced using multimodel direct inversion (MMDI) were analysed by two observers using the manual caliper technique. Except for two of the 108 individual datasets, when the agreement was moderate, there was substantial to perfect agreement between wave quality scores obtained by the two observers, with an identical mean value. Similarly, and again with only two exceptions, there was good to excellent agreement between the measurements of UT stiffness obtained by the two observers. UT stiffness values obtained when the acoustic waves were propagating along the principle muscle fibre direction were significantly higher than when the waves were propagating orthogonal to the principle muscle fibre direction at all vibration frequencies (p < 0.005), and only for the former was a significant dispersion effect observed whereby stiffness increased as frequency increased (p < 0.05). No significant asymmetry was observed in measurements of UT stiffness obtained for the left and right sides of the body (p = 0.29). In conclusion, the new soft and flexible tube-based actuator is comfortable and produced very good wave propagation in UT when positioned in either orientation. However, it is recommended for wave propagation to be induced in the principle fibre direction and there was found to be no advantage in using a vibration frequency above 60 Hz.