Evidence map›Paper›PMID 40008320›Full record

ArticleResuscitation plus2025

Defibrillation pad placement accuracy among Advanced Life Support instructors: A manikin-based observational study examining experience, self-evaluation, and actual performance.

Dennie Wulterkens, Freek Coumou, Cornelis Slagt, Reinier A Waalewijn, Lars Mommers

Abstract read
In one paragraph

Article in Resuscitation plus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Dennie WulterkensInstitute of Quality Medical Training Nieuwegein the Netherlands.
Freek CoumouHelicopter Emergency Medical Service Lifeliner 3 Nijmegen the Netherlands.
Cornelis SlagtHelicopter Emergency Medical Service Lifeliner 3 Nijmegen the Netherlands.
Reinier A WaalewijnDepartment of Cardiology Gelre Hospitals the Netherlands and St. Antonius Hospital Nieuwegein the Netherlands.
Lars MommersHelicopter Emergency Medical Service Lifeliner 3 Nijmegen the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Ventricular fibrillation is common in patients with out-of-hospital cardiac arrest. Early and effective defibrillation is important for their survival. Effective defibrillation depends highly on correct positioning of the defibrillation pads. Teaching this correctly by ALS instructors is therefore crucial. Methods: Fifty certified advanced life support instructors were recruited from a large training institute. Participants were asked to place defibrillation pads on an anatomically and real-weight (90 kg) manikin. Primary outcome was the placement of defibrillation pads placed in the sternal-apical and anterior-posterior positions. Secondary outcomes were performance self-assessment, defibrillation experience, self-perceived competence and self-efficacy in teaching defibrillation. These measures were evaluated using an 11-point Likert scale. Results: A total of 31 medical doctors and 19 registered nurses were enrolled in this study. Defibrillation pads were placed (mean ± SD) 42 ± 21 mm, 38 ± 23 mm, 35 ± 19 mm and 61 ± 48 mm from the reference point for the sternal, apical, anterior and posterior pads respectively, resulting in a respectively correct placement of 18%, 20%, 32% and 28%. The average number of correctly applied pads per instructor was 0.98 ± 0.74 out of four.Self-assessment of defibrillation pads placed by the participants were 8.56 ± 1.33 and 7.88 ± 1.64 for the sternal-apical and anterior-posterior positions respectively. Personal defibrillation experience showed that the majority had applied over 20 standard defibrillations. Experience with anterior-posterior pad placement was less and experience with bi-axillary and double sequential external defibrillation positions were absent in most participants. Self-perceived competence for the sternal-apical, anterior-posterior, bi-axillary and dual external synchronized positions were 8.68 ± 1.06, 8.08 ± 1.37, 5.57 ± 2.95 and 5.11 ± 2.67 respectively. Self-efficacy score for teaching defibrillation was 8.59 ± 0.81. No association was found between the number of correctly applied pads and any of the participants' variables. Conclusion: This study corroborates and expands upon existing knowledge regarding the challenges of defibrillator pad placement, revealing substantial variation in placement accuracy among instructors. Our novel analysis of pad angles and anterior-posterior analysis demonstrates that a significant portion of pads are incorrectly placed. These findings highlight the need for standardized approaches and improved training methodologies in defibrillator pad placement.

Indexed as

Cardiac arrestDefibrillationPads placementSimulationTeachingVentricular fibrillation

Identifiers

PMID40008320
PMCPMC11851189

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.