Evidence map›Paper›PMID 40008292›Full record

ArticleJournal of biomedical optics2025

Validation of subpixel target detection and linear spectral unmixing techniques on short-wave infrared hyperspectral images of collagen phantoms.

Hsian-Min Chen, Hsin-Che Wang, Chiu-Chin Sung, Yu-Ting Hsu, Yi-Jing Sheen

Abstract readValidation Study
In one paragraph

Article in Journal of biomedical optics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hsian-Min ChenTaichung Veterans General Hospital, Center for Quantitative Imaging in Medicine (CQUIM), Department of Medical Research, Taichung, Taiwan.
Hsin-Che WangTaichung Veterans General Hospital, Center for Quantitative Imaging in Medicine (CQUIM), Department of Medical Research, Taichung, Taiwan.
Chiu-Chin SungTaichung Veterans General Hospital, Center for Quantitative Imaging in Medicine (CQUIM), Department of Medical Research, Taichung, Taiwan.
Yu-Ting HsuTaichung Veterans General Hospital, Center for Quantitative Imaging in Medicine (CQUIM), Department of Medical Research, Taichung, Taiwan.
Yi-Jing SheenTaichung Veterans General Hospital, Division of Endocrinology and Metabolism, Department of Internal Medicine, Taichung, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Significance: We used three-dimensionally printed experimental molds and designed lard (lipid)-collagen mixed phantoms to simulate biological tissues to verify the practicality and accuracy of short-wave infrared (SWIR) hyperspectral imaging (HSI; 900 to 1700 nm), subpixel target detection (STD), and linear spectral unmixing (LSU). We provide a foundation for future development, validation, and reproducibility of hyperspectral image-processing techniques. Aim: We aim to verify the use of SWIR HSI in bionic tissue phantoms. Second, we focus on the accuracy of STD and spectral unmixing techniques in hyperspectral image processing. Finally, the penetration ability of the technology and its applications at various depths and concentrations are explored. Approach: All experiments were conducted using an SWIR (900 to 1700 nm) HSI sensor. Collagen phantoms of different thicknesses were created to test the penetration abilities. Lard (lipid) was embedded at different depths in the phantoms for STD, whereas LSU was performed on phantoms with varying collagen concentrations. The methods used included constrained energy minimization to detect the lard target and fully constrained least squares (FCLS) to estimate the abundance of collagen phantoms. Results: SWIR HSI effectively penetrated the collagen phantoms. Specifically, STD techniques can accurately detect the presence of lard (lipids) at depths of 7 to 20 mm in the collagen phantoms. Even at a depth of 68 mm, the detection accuracy was 0.907. Moreover, in the LSU analysis, the FCLS method accurately estimated the abundance of collagen phantoms at different concentrations, with a correlation coefficient of 0.9917, indicating high accuracy across different concentrations. Conclusions: This study demonstrated that SWIR HSI is highly accurate for deep target detection and LSU. This technology has great potential for use in future noninvasive biomedical diagnostic models. Collagen phantoms are valuable tools for validating HSI algorithms and provide a solid foundation for clinical applications.

Indexed as

CollagenHyperspectral ImagingImage Processing, Computer-AssistedPhantoms, ImagingLipidsReproducibility of ResultsCollagenLipidscollagen phantomsconstrained energy minimizationfully constrained least squareslinear spectral unmixingshort-wave infrared hyperspectral imagingsubpixel target detection

Identifiers

PMID40008292
PMCPMC11853843

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.