ArticleHealthcare technology letters
Signal-quality-aware multisensor fusion for atrial fibrillation detection.
Article in Healthcare technology letters. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Biomechanical Monitoring of Exercise Fatigue Using Wearable Devices: A Review.Bioengineering (Basel, Switzerland) · 2025Review
- Signal-quality-aware multisensor fusion for atrial fibrillation detection.Healthcare technology lettersArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This letter introduces a novel method to enhance atrial fibrillation detection accuracy in healthcare monitoring. Wearable devices often face inconsistent signal quality due to noise. To address this, a multimodal data fusion technique that improves signal reliability during continuous monitoring is proposed. The method improves the precision of detecting R-R intervals by integrating wavelet coefficients from electrocardiogram, photoplethysmogram, and arterial blood pressure signals, weighted according to the quality of each signal. Furthermore, a bi-directional long short-term memory network is developed to accurately detect AF based on the derived heartrate or R-R intervals. Unlike prior studies, this work uniquely evaluates the system's performance under noisy conditions, demonstrating significant accuracy improvements over single-channel methods. The system's generalizability is confirmed by evaluating the classifier's performance as the number of sensor inputs increases. At a signal-to-noise ratio of -10 dB, the accuracy improves by 4.51% with two sensor inputs and by 10.92% with three inputs, compared to using a single input.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.