Evidence map›Paper›PMID 40006462›Full record

ArticleSensors (Basel, Switzerland)2025

Smooth Moves: Comparing Log Dimensionless Jerk Metrics from Body Center of Mass Trajectory and Wearable Sensor Acceleration During Walking.

Paolo Brasiliano, Gaspare Pavei, Elena Bergamini

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Paolo BrasilianoDepartment of Motor, Human and Health Sciences, University of Rome "Foro Italico", 00135 Roma, Italy.ORCID 0000-0003-2545-3930
Gaspare PaveiDepartment of Pathophysiology and Transplantation, University of Milan, 20133 Milano, Italy.ORCID 0000-0002-0109-4964
Elena BergaminiDepartment of Management, Information and Production Engineering, University of Bergamo, 24129 Bergamo, Italy.ORCID 0000-0002-9055-3981

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Movement smoothness is a critical metric for evaluating motor control and sensorimotor impairments, with increasing relevance in neurorehabilitation and everyday functional assessments. This study investigates the correlation between two smoothness metrics (Log Dimensionless Jerk): LDLJV, derived from body center of mass (BCoM) trajectories using a gold-standard stereophotogrammetric system, and LDLJA, calculated from acceleration data recorded via an inertial measurement unit (IMU) placed at the L1-L2 level. Ten healthy adults (six men and four women; height: 1.71 ± 0.08 m; body mass: 68.2 ± 10.2 kg; age: 34.5 ± 8.5 years) walked on a treadmill at seven different speeds, with stride-specific data analyzed to compute smoothness indices for three anatomical components (antero-posterior, medio-lateral, cranio-caudal). Concordance between the metrics was evaluated using Bland-Altman analysis, Spearman's correlation, and the mean absolute percentage error. The results revealed weak correlations and substantial biases across all components and speeds, reflecting inherent differences between IMU- and BCoM-derived data. Correcting biases improved alignment but did not eliminate discrepancies. The findings highlight that LDLJA captures only localized trunk accelerations, whereas BCoM-derived LDLJV approximates whole-body dynamics, making direct substitution infeasible. This study emphasizes the need for careful interpretation of IMU-based metrics and contributes to refining their application in real-world gait analyses.

Indexed as

WalkingWearable Electronic DevicesAccelerationAdultBiomechanical PhenomenaFemaleGaitHumansMalebody center of massgait analysisinertial measurement unit (IMU)LDLJmovement smoothness

Identifiers

PMID40006462
PMCPMC11860695

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.