Evidence map›Paper›PMID 40006308›Full record

ArticleSensors (Basel, Switzerland)2025

Optimisation and Comparison of Markerless and Marker-Based Motion Capture Methods for Hand and Finger Movement Analysis.

Valentin Maggioni, Christine Azevedo-Coste, Sam Durand, François Bailly

Abstract readComparative Study
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Video-based finger kinematics for degenerative cervical myelopathy: a smartphone-based computer vision approach for screening.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Valentin MaggioniContrôle Artificiel de Mouvements et de Neuroprothèses Intuitives (CAMIN), Institut National de Recherche en Informatique et en Automatique (INRIA), Centre d'Université Côte d'Azur, Université de Montpellier, 34090 Montpellier, France.ORCID 0009-0009-5095-4279
Christine Azevedo-CosteContrôle Artificiel de Mouvements et de Neuroprothèses Intuitives (CAMIN), Institut National de Recherche en Informatique et en Automatique (INRIA), Centre d'Université Côte d'Azur, Université de Montpellier, 34090 Montpellier, France.ORCID 0000-0002-7379-8004
Sam DurandContrôle Artificiel de Mouvements et de Neuroprothèses Intuitives (CAMIN), Institut National de Recherche en Informatique et en Automatique (INRIA), Centre d'Université Côte d'Azur, Université de Montpellier, 34090 Montpellier, France.
François BaillyContrôle Artificiel de Mouvements et de Neuroprothèses Intuitives (CAMIN), Institut National de Recherche en Informatique et en Automatique (INRIA), Centre d'Université Côte d'Azur, Université de Montpellier, 34090 Montpellier, France.ORCID 0000-0002-7737-8269

Funding

EIC PATHFINDER AI-HAND 1099916
6 · The paper itself

Abstract

Ensuring the accurate tracking of hand and fingers movements is an ongoing challenge for upper limb rehabilitation assessment, as the high number of degrees of freedom and segments in the limited volume of the hand makes this a difficult task. The objective of this study is to evaluate the performance of two markerless approaches (the Leap Motion Controller and the Google MediaPipe API) in comparison to a marker-based one, and to improve the precision of the markerless methods by introducing additional data processing algorithms fusing multiple recording devices. Fifteen healthy participants were instructed to perform five distinct hand movements while being recorded by the three motion capture methods simultaneously. The captured movement data from each device was analyzed using a skeletal model of the hand through the inverse kinematics method of the OpenSim software. Finally, the root mean square errors of the angles formed by each finger segment were calculated for the markerless and marker-based motion capture methods to compare their accuracy. Our results indicate that the MediaPipe-based setup is more accurate than the Leap Motion Controller-based one (average root mean square error of 10.9° versus 14.7°), showing promising results for the use of markerless-based methods in clinical applications.

Indexed as

FingersHandAdultAlgorithmsBiomechanical PhenomenaFemaleHumansMaleMotionMotion CaptureMovementSoftwareecological movementshand and finger kinematicsmarkerless motion captureskeletal model

Identifiers

PMID40006308
PMCPMC11858933

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.