Evidence map›Paper›PMID 40006228›Full record

ArticleSensors (Basel, Switzerland)2025

Thermoelectric Measuring Equipment for Perioperative Monitoring of Temperature and Heat Flux Density of the Human Eye in Vitreoretinal Surgery.

Roman Kobylianskyi, Krzysztof Przystupa, Valentyn Lysko, Jacek Majewski, Lyudmyla Vikhor, Vadym Boichuk, Oleg Zadorozhnyy, Orest Kochan, Mykola Umanets, Nataliya Pasyechnikova

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Roman KobylianskyiInstitute of Thermoelectricity of the NAS and MES of Ukraine, 58029 Chernivtsi, Ukraine.
Krzysztof PrzystupaDepartment of Automation, Lublin University of Technology, Nadbystrzycka 38D, 20-618 Lublin, Poland.ORCID 0000-0003-4361-2763
Valentyn LyskoInstitute of Thermoelectricity of the NAS and MES of Ukraine, 58029 Chernivtsi, Ukraine.ORCID 0000-0001-7994-6795
Jacek MajewskiDepartment of Automatics and Metrology, Lublin University of Technology, Nadbystrzycka 38D, 20-618 Lublin, Poland.
Lyudmyla VikhorInstitute of Thermoelectricity of the NAS and MES of Ukraine, 58029 Chernivtsi, Ukraine.ORCID 0000-0002-8065-0526
Vadym BoichukInstitute of Thermoelectricity of the NAS and MES of Ukraine, 58029 Chernivtsi, Ukraine.
Oleg ZadorozhnyyInstitute of Thermoelectricity of the NAS and MES of Ukraine, 58029 Chernivtsi, Ukraine.ORCID 0000-0003-0125-2456
Orest KochanDepartment of Measuring Information Technologies, Institute of Computer Technologies, Automation and Metrology, Lviv Polytechnic National University, Stepana Bandery Str. 12, 79013 Lviv, Ukraine.ORCID 0000-0002-3164-3821
Mykola UmanetsState Institution "The Filatov Institute of Eye Diseases and Tissue Therapy of the National Academy of Medical Sciences of Ukraine", 65015 Odesa, Ukraine.ORCID 0000-0001-5533-1956
Nataliya PasyechnikovaState Institution "The Filatov Institute of Eye Diseases and Tissue Therapy of the National Academy of Medical Sciences of Ukraine", 65015 Odesa, Ukraine.ORCID 0000-0001-5718-8700

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Perioperative monitoring of the ocular heat transfer is important for increasing the safety of long-term vitreoretinal surgery. The study is aimed at studying new thermoelectric measuring devices for comprehensive perioperative monitoring of ocular temperature and heat fluxes in vitreoretinal surgery. This pilot, open-label, prospective study included 23 patients (23 eyes) with proliferative diabetic retinopathy (PDR) in both eyes. The thermoelectric devices were developed for measuring intraocular temperature in vitreoretinal surgery and for determining the ocular surface temperature (OST) and heat flux (HF) density. In all cases, OST and HF density of both eyes were recorded (before and after surgery). Intraocular temperature and temperature of the irrigation fluid were measured intraoperatively. No complications associated with the perioperative use of thermoelectric temperature and HF sensors were identified during the study. The successful application of thermoelectric temperature and HF sensors, developed specifically for ophthalmological applications, in comprehensive perioperative monitoring of ocular heat transfer in patients with PDR in vitreoretinal surgery was demonstrated for the first time. Further research is needed to confirm the benefits of perioperative temperature monitoring in vitreoretinal surgery, as well as to develop equipment for active management of temperature in surgical practice.

Indexed as

EyeVitreoretinal SurgeryAdultAgedBody TemperatureDiabetic RetinopathyFemaleHot TemperatureHumansMaleMiddle AgedMonitoring, PhysiologicProspective StudiesTemperatureheat fluxproliferative diabetic retinopathytemperaturethermoelectric devicevitreoretinal surgery

Identifiers

PMID40006228
PMCPMC11858991

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.