ArticleBioengineering (Basel, Switzerland)2025
A High-Frequency Temporal-Interference Alternative Current Stimulation Device Using Pulse Amplitude Modulation with Push-Pull Current Sources.
Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Transcranial Temporal Interference Stimulation: A Brief Review of Architectures, Circuits, and Application Challenges.IEEE open journal of engineering in medicine and biology · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
This study proposes a high-frequency Pulse Amplitude-Modulation Temporal-Interference (PAM-TI) current stimulation device, which utilizes two sets of Amplitude-modulated transcranial alternating current stimulation (AM-tACS): one AM frequency at f0 (where f0 = 2 kHz) (source 1) and the other AM frequency at f1 = f0 + △f (where f1 = 2.01 kHz) (source 2), to generate a △f (where △f = 10 Hz) envelope modulated at a fc (where fc = 100 kHz) high carrier frequency. The high carrier frequency reduces body impedance and conserves more stimulation power, allowing it to penetrate the skin and reach the subcutaneous region. The proposed PAM-TI technique elevates the two current sources to a 100 kHz carrier frequency. Instead of the challenges associated with generating high-frequency stimulation currents using an MCU and DAC, the proposed PAM-TI stimulation device achieves this by simply utilizing a pair of complementary pulse-width modulations (PWMs). The push-pull technique is employed to balance the charging currents between the anode and cathode, synchronizing the current timing of Source 1 and Source 2 under the fc modulation condition. To minimize signal attenuation, the PAM circuit is integrated directly into the electrode, ensuring the high-frequency signal is generated close to the body and preventing degradation from long wires. Additionally, a dry pin-type spring-loaded electrode is used to reduce interference caused by hair when placed on the head. The device's validity and current directionality were verified using a scalp tissue-mimicking phantom composed of agar and saline.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.