Evidence map›Paper›PMID 40001630›Full record

ArticleBioengineering (Basel, Switzerland)2025

A Novel Mechanics-Based Design for Overcorrection in Clear Aligner Orthodontics via Finite Element Analysis.

Sensen Yang, Yumin Cheng

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Sensen YangShanghai Key Laboratory of Mechanics in Energy Engineering, Shanghai Institute of Applied Mathematics and Mechanics, School of Mechanics and Engineering Science, Shanghai University, Shanghai 200072, China.
Yumin ChengShanghai Key Laboratory of Mechanics in Energy Engineering, Shanghai Institute of Applied Mathematics and Mechanics, School of Mechanics and Engineering Science, Shanghai University, Shanghai 200072, China.ORCID 0000-0002-0967-4111

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A simplified mechanics model of aligner-tooth interaction was developed to establish a precise computational method for overcorrection design in clear aligner orthodontics. Validated through finite element analysis and experiments, the results demonstrated that designing the movement of only the target teeth on the aligner leads to uneven force distribution on adjacent teeth, while an overcorrection design can evenly distribute the reaction force generated by pushing the target teeth to the anchorage teeth, reducing the maximum force on the anchorage teeth, minimizing unplanned tooth movement, and improving the efficacy of the designed tooth movement for all teeth.

Indexed as

clear alignerfinite element analysismolar distalizationovercorrection

Identifiers

PMID40001630
PMCPMC11852136

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.