Evidence map›Paper›PMID 40000182›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2025

[Biomechanical effects of medial and lateral translation deviations of femoral components in unicompartmental knee arthroplasty on tibial prosthesis fixation].

Jingting Xu, Jing Zhang, Bing Zhang, Wen Cui, Weijie Zhang, Zhenxian Chen

Abstract readEnglish Abstract
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jingting XuSchool of Construction Machinery, Chang'an University, Xi'an 710064, P. R. China.
Jing ZhangSchool of Construction Machinery, Chang'an University, Xi'an 710064, P. R. China.
Bing ZhangSchool of Construction Machinery, Chang'an University, Xi'an 710064, P. R. China.
Wen CuiSchool of Construction Machinery, Chang'an University, Xi'an 710064, P. R. China.
Weijie ZhangHonghui Hospital, Xi'an Jiaotong University, Xi'an 710054, P. R. China.
Zhenxian ChenSchool of Construction Machinery, Chang'an University, Xi'an 710064, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Prosthesis loosening is the leading cause of postoperative revision in unicompartmental knee arthroplasty (UKA). The deviation of medial and lateral translational installation of the prosthesis during surgery is a common clinical phenomenon and an important factor in increasing the risk of prosthesis loosening. This study established a UKA finite element model and a bone-prosthesis fixation interface micromotion prediction model. The predicted medial contact force and joint motion of the knee joint from a patient-specific lower extremity musculoskeletal multibody dynamics model of UKA were used as boundary conditions. The effects of 9 femoral component medial and lateral translational installation deviations on the Von Mises stress of the proximal tibia, the contact stress, and the micro-motion of the bone prosthesis fixation interface were quantitatively studied. It was found that compared with the neutral position (a/A of 0.492), the lateral translational deviation of the femoral component significantly increased the tibial Von Mises stress and the bone-prosthesis fixation interface contact stress. The maximum Von Mises stress and the maximum contact stress of the fixation interface increased by 14.08% and 143.15%, respectively, when a/A was 0.361. The medial translational deviation of the femoral component significantly increased the bone-prosthesis fixation interface micro-motion. The maximum value of micromotion under the conditions of femoral neutral and medial translation deviation was in the range of 20-50 μm, which is suitable for osseointegration. Therefore, based on considerations such as the micromotion range suitable for osseointegration reported in the literature, the risk of reducing prosthesis loosening, and factors that may induce pain, it is recommended that clinicians control the mounting position of the femoral component during surgery within the safe range of 0-4 mm medial translation deviation.

Indexed as

Arthroplasty, Replacement, KneeFemurKnee ProsthesisTibiaBiomechanical PhenomenaFinite Element AnalysisHumansKnee JointProsthesis DesignProsthesis FailureStress, MechanicalFixation interface micromotionInstallation deviationMedial-lateral translationUnicondylar knee arthroplasty

Identifiers

PMID40000182
PMCPMC11955340

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked