Evidence map›Paper›PMID 39999127›Full record

ArticlePloS one2025

Measurement accuracy and cutoffs for predicting primary aldosteronism diagnosis using Lumipulse® for renin and aldosterone measurements.

Maude Laney, Appoline Nabi-Bourgois, Julien Mallart-Riancho, Simon Travers, Mouna Chebbi, Aurore Kling, Laurence Amar, Stephanie Baron

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Maude LaneyPhysiology Department, AP-HP, Georges Pompidou European Hospital, Paris, France.
Appoline Nabi-BourgoisPhysiology Department, AP-HP, Georges Pompidou European Hospital, Paris, France.
Julien Mallart-RianchoHypertension Unit, AP-HP, Georges Pompidou European Hospital, Paris, France.ORCID 0000-0002-3002-1780
Simon TraversPhysiology Department, AP-HP, Georges Pompidou European Hospital, Paris, France.
Mouna ChebbiPhysiology Department, AP-HP, Georges Pompidou European Hospital, Paris, France.
Aurore KlingPhysiology Department, AP-HP, Georges Pompidou European Hospital, Paris, France.
Laurence AmarHypertension Unit, AP-HP, Georges Pompidou European Hospital, Paris, France.
Stephanie BaronPhysiology Department, AP-HP, Georges Pompidou European Hospital, Paris, France.ORCID 0000-0002-0375-6968

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesPrimary aldosteronism (PA) diagnosis is a multistep process that begins with screening based on the plasma aldosterone-to-renin ratio (ARR). As cut-off values depend on the methods used, the aim of this study was 1) to validate the performances of new aldosterone and renin chemiluminescent immuno-assays using the Lumipulse® analyzer (Fujirebio®) and then 2) to define the criteria to distinguish PA patients from those with essential hypertension (EH).

methodsThis monocentric retrospective study included 297 patients admitted to Georges Pompidou European Hospital, France, between January 2021 and December 2022 for the assessment of hypertension etiology. We evaluated analytical performances and compared Lumipulse® results for plasma renin (PRC) and plasma aldosterone (PAC) concentrations (n = 196) as well as 24-hour urine aldosterone excretion (24UA) (n = 201) to the reference methods (PRC: Liaison XL® Diasorin®; PAC and 24UA: LC-MS/MS). Receiver operating characteristic curve analysis was used to define the cut-off values for ARR, PAC, and 24UA to distinguish between PA and EH patients.

resultsAnalytical characteristics were in accordance with requested performances. Our results showed excellent correlations between Lumipulse® and our reference methods. We propose cut-off values of 35 pmol/mIU as the ARR, 260 pmol/L for PAC, and 49 nmol/24h for 24UA for predicting PA diagnosis.

conclusionsLumipulse® (Fujirebio®) is a reliable alternative for measuring PRC, PAC, and 24UA for predicting PA diagnosis with the use of corresponding cut-off values for each criterion.

Indexed as

AldosteroneHyperaldosteronismReninAdultAgedEssential HypertensionFemaleHumansMaleMiddle AgedRetrospective StudiesROC CurveAldosteroneRenin

Identifiers

PMID39999127
PMCPMC11856259

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.