Evidence map›Paper›PMID 39998773›Full record

ArticleThe Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology2025

Efficacy and safety of mechanical transvenous lead extraction: median follow-up analysis and development of an experimental model for predicting survival post-extraction.

Shima Nasri, Sahar Samimi, Masoud Eslami, Khashayar Hematpour, Morteza Eslami, Hirad Yarmohammadi, Reza Mollazadeh, Mehrzad Rahmanian

Abstract read
In one paragraph

Article in The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shima NasriImam Khomeini Hospital Complex, Tehran University of Medical Sciences, Islamic Republic of Iran, Tehran.
Sahar SamimiMcGovern Medical School, University of Texas, Houston, USA.
Masoud EslamiImam Khomeini Hospital Complex, Tehran University of Medical Sciences, Islamic Republic of Iran, Tehran.
Khashayar HematpourMcGovern Medical School, University of Texas, Houston, USA.
Morteza EslamiImam Khomeini Hospital Complex, Tehran University of Medical Sciences, Islamic Republic of Iran, Tehran.
Hirad YarmohammadiColumbia University Vagelos College of Physicians and Surgeons, New York, USA.
Reza MollazadehImam Khomeini Hospital Complex, Tehran University of Medical Sciences, Islamic Republic of Iran, Tehran. mollazar@yahoo.com.
Mehrzad RahmanianImam Khomeini Hospital Complex, Tehran University of Medical Sciences, Islamic Republic of Iran, Tehran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCardiac implantable electronic device (CIED) implantation is on the rise, accompanied by an increase in its inevitable complications such as different types of CIED infections that require further therapy and potential device extraction. Ensuring efficacy and safety remains paramount in transvenous lead extraction (TLE), given the complex nature of the procedure. The purpose of this study is to assess the outcomes of relatively low-cost mechanical TLE, including mid-term clinical follow-up, and to develop a predictive model for post-TLE survival. This study included all consecutive patients admitted for TLE at two tertiary medical centers between 2016 and 2021. Baseline characteristics, TLE procedure details complications occurring during and/or after the procedure and follow-up outcomes were collected.

resultsDuring the 5-year period, 100 consecutive patients underwent TLE. The mean age of the subjects was 61 ± 3 years. The average time from lead implantation to TLE was 69.34 ± 9.36 months, with a total of 216 leads extracted. The most common indication for TLE was infection observed in 87% of subjects with pocket infection seen in the majority (84%). Complete clinical success was achieved in 98% of patients, with major complications occurred in 5% of cases and only one case of peri-procedural death. Proposed experimental model showed that near 50% of the patients will live less than 73.29 months.

conclusionTLE demonstrated a high level of safety with low mortality and morbidity rates. Using low cost widely available mechanical tools is useful for treating CIED-related infections.

Indexed as

Cardiac implantable electronic deviceDevice erosionDevice infectionEndocarditisLead removalPocket infectionTransvenous lead extraction