Evidence map›Paper›PMID 39997598›Full record

ArticleJournal of functional biomaterials2025

Customized Titanium Plates for Preventing Mandibular Fractures in Lower Third Molar Extractions.

Cezara Andreea Onică, Costin Iulian Lupu, Elena-Raluca Baciu, Gabriela Luminița Gelețu, Alice Murariu, Dana Gabriela Budală, Ionuț Luchian, Neculai Onică

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Cezara Andreea OnicăDepartment of Surgery, Faculty of Dental Medicine, University of Medicine and Pharmacy "Grigore T. Popa", 700115 Iasi, Romania.
Costin Iulian LupuDepartment of Implantology, Removable Dentures, Dental Technology, Faculty of Dental Medicine, University of Medicine and Pharmacy "Grigore T. Popa", 700115 Iasi, Romania.
Elena-Raluca BaciuDepartment of Implantology, Removable Dentures, Dental Technology, Faculty of Dental Medicine, University of Medicine and Pharmacy "Grigore T. Popa", 700115 Iasi, Romania.ORCID 0000-0001-8932-6784
Gabriela Luminița GelețuDepartment of Surgery, Faculty of Dental Medicine, University of Medicine and Pharmacy "Grigore T. Popa", 700115 Iasi, Romania.ORCID 0009-0000-1340-1418
Alice MurariuDepartment of Surgery, Faculty of Dental Medicine, University of Medicine and Pharmacy "Grigore T. Popa", 700115 Iasi, Romania.
Dana Gabriela BudalăDepartment of Implantology, Removable Dentures, Dental Technology, Faculty of Dental Medicine, University of Medicine and Pharmacy "Grigore T. Popa", 700115 Iasi, Romania.ORCID 0000-0003-2312-6987
Ionuț LuchianDepartment of Periodontology, Faculty of Dental Medicine, University of Medicine and Pharmacy "Grigore T. Popa", 700115 Iasi, Romania.ORCID 0000-0003-0017-9672
Neculai OnicăDepartment of Surgery, Faculty of Dental Medicine, University of Medicine and Pharmacy "Grigore T. Popa", 700115 Iasi, Romania.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The extraction of deeply impacted lower third molars is a common yet challenging surgical procedure associated with complications such as mandibular fractures, pain, and swelling. This study evaluated the effectiveness of customized 3D-printed titanium plates in reducing the risk of intraoperative iatrogenic mandibular fractures. This innovative approach aims to improve surgical outcomes, enhance patient safety, and boost confidence for both surgeons and patients. Eighteen patients with Pell and Gregory class II/IIIC impacted lower third molars underwent preoperative CBCT scans, which facilitated the design and fabrication of customized plates and drilling guides. The surgical procedure involved incision, flap elevation, precise plate placement, osteotomy, odontotomy, extraction, and the postoperative assessment of pain, swelling, trismus, and anxiety using validated scales and facial scanning. The results show that customized titanium plates successfully prevented mandibular fractures in all cases. Although initial postoperative discomfort, including swelling, trismus, and pain, was observed, significant improvements occurred within one week. This technique provided structural reinforcement during surgery and healing without adverse events or fractures. Customized 3D-printed titanium plates represent a safe and effective solution for minimizing mandibular fractures, offering promising improvements in surgical outcomes.

Indexed as

3D printingcustomized titanium platefacial scannerthird molar extraction

Identifiers

PMID39997598
PMCPMC11856432

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.