Evidence map›Paper›PMID 39997573›Full record

ArticleJournal of functional biomaterials2025

Comparative Biomechanical Evaluation of Novel Screwless Retained Dental Implant Prosthesis: A 3D Finite Element Analysis.

Ki-Sun Lee, Jaeyeol Kim, JaeHyung Lim, Jae-Jun Ryu

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ki-Sun LeeDepartment of Prosthodontics, Korea University Ansan Hospital, Ansan-si 15355, Republic of Korea.ORCID 0000-0002-6933-3589
Jaeyeol KimDepartment of Medicine, Graduate School, Korea University, Seoul 02841, Republic of Korea.
JaeHyung LimDepartment of Oral & Maxillofacial Surgery, Korea University Ansan Hospital, Ansan-si 15355, Republic of Korea.ORCID 0000-0001-5874-1918
Jae-Jun RyuDepartment of Prosthodontics, Korea University Anam Hospital, Seoul 02841, Republic of Korea.ORCID 0000-0001-6903-5955

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to comparatively evaluate the biomechanical behaviors of three types of dental implant restorations: a screw-and-cement-retained prosthetic system (SCRP); a cementless screw-retained prosthetic system (SRP); and a novel screwless hook-retained prosthetic system (HRP). Three-dimensional finite element analysis (FEA) was used to evaluate biomechanical behavior. A comparative study of three dental implant prostheses was performed under two loading conditions: a vertical load of 100 N and an oblique load of 100 N at an angle of 30°. Under both loading conditions, the maximum von Mises stress values in the dental implant using the HRP system were lower (21.33 MPa) than those of the SCRP system (32.91 MPa), and the stress distribution of the implant prosthetic components tended to be more favorable than that of the SCRP system. Thus, the results show that the performance of the HRP system was comparable to that of a conventional SRP system under the same conditions. Regarding stress distribution, the novel screwless HRP system presents a viable alternative implant prosthodontic system to the conventional SCRP system.

Indexed as

cementless screw-retaineddental implant prosthesisfinite element analysis

Identifiers

PMID39997573
PMCPMC11856067

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked