Evidence map›Paper›PMID 39997145›Full record

ArticleBiomimetics (Basel, Switzerland)2025

Biomimicry-Based Design of Underground Cold Storage Facilities: Energy Efficiency and Sustainability.

Mugdha Kshirsagar, Sanjay Kulkarni, Ankush Kumar Meena, Danby Caetano D'costa, Aroushi Bhagwat, Md Irfanul Haque Siddiqui, Dan Dobrotă

Abstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mugdha KshirsagarDepartment of Civil Engineering, Symbiosis Institute of Technology, Symbiosis International University, Near Lupin Research Park, Gram: Lavale, Tal: Mulshi, Pune 412115, Maharashtra, India.ORCID 0000-0001-5364-2064
Sanjay KulkarniDepartment of Civil Engineering, Symbiosis Institute of Technology, Symbiosis International University, Near Lupin Research Park, Gram: Lavale, Tal: Mulshi, Pune 412115, Maharashtra, India.
Ankush Kumar MeenaDepartment of Civil Engineering, Symbiosis Institute of Technology, Symbiosis International University, Near Lupin Research Park, Gram: Lavale, Tal: Mulshi, Pune 412115, Maharashtra, India.
Danby Caetano D'costaDepartment of Civil Engineering, Symbiosis Institute of Technology, Symbiosis International University, Near Lupin Research Park, Gram: Lavale, Tal: Mulshi, Pune 412115, Maharashtra, India.
Aroushi BhagwatDepartment of Civil Engineering, Symbiosis Institute of Technology, Symbiosis International University, Near Lupin Research Park, Gram: Lavale, Tal: Mulshi, Pune 412115, Maharashtra, India.
Md Irfanul Haque SiddiquiDepartment of Mechanical Engineering, College of Engineering, King Saud University, Riyadh 12372, Saudi Arabia.ORCID 0000-0003-4289-4826
Dan DobrotăFaculty of Engineering, Department of Industrial Engineering and Management, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania.ORCID 0000-0002-2202-7701

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Underground cold storage gives rise to special challenges that require innovative solutions to ensure maximum energy efficiency. Conventional energy systems tend to be based on high energy use, so sustainable solutions are crucial. This study explores the novel idea of biomimetics and how it might be used in the planning and building of underground cold storage facilities as well as other infrastructure projects. Biomimetic strategies, inspired by termite mounds, gentoo penguin feathers, and beehive structures, are applied to minimize reliance on energy-intensive cooling systems. These natural models offer efficient thermal regulation, airflow optimization, and passive cooling mechanisms such as geothermal energy harvesting. The integration of naturally driven convection and ventilation ensures stable internal temperatures under varying conditions. Biomimicry was employed in Revit Architecture, coupled with structural optimization, to eliminate urban space's limitations and further increase energy efficiency. The analytical work for this paper utilized a set of formulas that represent heat flow, thermal resistance, R-value, thermal transmittance, U-value, solar absorption, and G-value. The results pointed to very good insulation, with exterior walls having an R-value of 10.2 m

Indexed as

biomimicryenergy conservationsustainabilityunderground cold-storage

Identifiers

PMID39997145
PMCPMC11853035

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.