Evidence map›Paper›PMID 39996968›Full record

ArticleBiosensors2025

Development and Optimization of a Cost-Effective Electrochemical Immunosensor for Rapid COVID-19 Diagnosis.

Thaís Machado Lima, Daiane Martins Leal, Zirlane Coelho Ferreira, Fernando de Jesus Souza, Danilo Bretas de Oliveira, Etel Rocha-Vieira, Helen Rodrigues Martins, Arnaldo César Pereira, Lucas Franco Ferreira

Abstract read
In one paragraph

Article in Biosensors, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Thaís Machado LimaInstitute of Science and Technology, Federal University of the Jequitinhonha and Mucuri Valleys (UFVJM), Diamantina 39100-000, Minas Gerais, Brazil.
Daiane Martins LealInstitute of Science and Technology, Federal University of the Jequitinhonha and Mucuri Valleys (UFVJM), Diamantina 39100-000, Minas Gerais, Brazil.
Zirlane Coelho FerreiraInstitute of Science and Technology, Federal University of the Jequitinhonha and Mucuri Valleys (UFVJM), Diamantina 39100-000, Minas Gerais, Brazil.
Fernando de Jesus SouzaFaculty of Medicine, Federal University of the Jequitinhonha and Mucuri Valleys (UFVJM), Diamantina 39100-000, Minas Gerais, Brazil.
Danilo Bretas de OliveiraFaculty of Medicine, Federal University of the Jequitinhonha and Mucuri Valleys (UFVJM), Diamantina 39100-000, Minas Gerais, Brazil.
Etel Rocha-VieiraFaculty of Medicine, Federal University of the Jequitinhonha and Mucuri Valleys (UFVJM), Diamantina 39100-000, Minas Gerais, Brazil.ORCID 0000-0001-6908-7237
Helen Rodrigues MartinsPharmacy Department, Federal University of the Jequitinhonha and Mucuri Valleys (UFVJM), Diamantina 39100-000, Minas Gerais, Brazil.ORCID 0000-0002-5786-7524
Arnaldo César PereiraDepartment of Natural Sciences, Federal University of São João del-Rei (UFSJ), São João del-Rei 36307-352, Minas Gerais, Brazil.ORCID 0000-0003-2864-3756
Lucas Franco FerreiraInstitute of Science and Technology, Federal University of the Jequitinhonha and Mucuri Valleys (UFVJM), Diamantina 39100-000, Minas Gerais, Brazil.ORCID 0000-0002-5431-0069

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The coronavirus disease (COVID-19) pandemic has created an urgent need for rapid, accurate, and cost-effective diagnostic tools. In this study, an economical electrochemical immunosensor for the rapid diagnosis of COVID-19 was developed and optimized based on charge transfer resistance (Rct) values obtained by electrochemical impedance spectroscopy (EIS) from the interaction between antibodies (anti-SARS-CoV-2) immobilized as a bioreceptor and the virus (SARS-CoV-2). The sensor uses modified pencil graphite electrodes (PGE) coated with poly(4-hydroxybenzoic acid), anti-SARS-CoV-2, and silver nanoparticles. The immobilization of anti-SARS-CoV-2 antibodies was optimized at a concentration of 1:250 for 30 min, followed by blocking the surface with 0.01% bovine serum albumin for 10 min. The optimal conditions for virus detection in clinical samples were a 1:10 dilution with a response time of 20 min. The immunosensor responded linearly in the range of 0.2-2.5 × 10

Indexed as

Biosensing TechniquesCOVID-19ElectrochemistryRapid Diagnostic TestsAntibodies, ImmobilizedGraphiteHumansMetal NanoparticlesMucusReproducibility of ResultsSARS-CoV-2Sensitivity and SpecificityAntibodies, ImmobilizedGraphite4-hydroxybenzoic acidelectrochemical platformselectropolymerizationpencil graphite electrodesSARS-CoV-2

Identifiers

PMID39996968
PMCPMC11853419

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.