Evidence map›Paper›PMID 39994741›Full record

ArticleBiomedical engineering online2025

Design and validation of an alignment free adaptive joint torque measurement system.

Lei Li, Jingcheng Chen, Shaoming Sun, Wei Peng

Abstract readValidation Study
In one paragraph

Article in Biomedical engineering online, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Lei LiHefei Institutes of Physical Science, Chinese Academy of Sciences, 350 Shushan Lake Road, Hefei, 230031, China.
Jingcheng ChenCAS Hefei Institute of Technology Innovation, Hefei, 230088, China.
Shaoming SunHefei Institutes of Physical Science, Chinese Academy of Sciences, 350 Shushan Lake Road, Hefei, 230031, China. ssmjkcjzxll@outlook.com.
Wei PengHefei Institutes of Physical Science, Chinese Academy of Sciences, 350 Shushan Lake Road, Hefei, 230031, China. wpeng@iim.ac.cn.

Funding

Anhui Provincial Department of Science and Technology 202304a05020078
6 · The paper itself

Abstract

purposeThis study introduces a transferable alignment-free adaptive joint torque measurement (AFAJTM) system designed to resolve inconsistencies in torque measurements caused by misalignment between dynamometer and joint rotational axes, improving accuracy and reliability in joint torque assessment.

methodThis study presents the design and control methodology of an alignment free adaptive joint torque measurement system. An elbow joint torque measurement device (EJTMD) was developed, and its torque consistency and repeatability were evaluated at various misalignment positions using a joint simulation model. Clinical experiments compared torque measurements between the EJTMD and a traditional standard dynamometer during maximum voluntary contraction (MVC) tests at different misalignment positions.

resultThe simulation test results demonstrate that the AFAJTM system can achieve high-precision torque measurements, with measurement errors controlled within ± 0.5 Nm at various misalignment positions. Clinical experiment data show that the EJTMD exhibits high consistency in torque measurements compared to the traditional standard dynamometer across five different misalignment positions, with strong repeatability and reliability.

conclusionThe AFAJTM system provides a novel solution for joint torque measurement under human-machine axis misalignment conditions, a solution that eliminates the need for axis alignment, effectively overcoming the limitations of traditional measurement devices. This system can be widely applied in various devices that require joint torque measurement, demonstrating excellent adaptability and high-precision measurement capabilities.

Indexed as

Elbow JointJointsTorqueAdultEquipment DesignHumansMaleReproducibility of ResultsAdaptabilityAlignment-freeAutomaticallyDynamometerHuman–machineJoint torqueMeasurementMisalignmentMVC testRehabilitation

Identifiers

PMID39994741
PMCPMC11852568

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.