Evidence map›Paper›PMID 39992544›Full record

ArticlePhysical and engineering sciences in medicine2025

Enhancing intrafraction position monitoring for prostate radiotherapy on a conventional linear accelerator: an optimization study.

Sankar Arumugam

Abstract read
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Sankar ArumugamDepartment of Medical Physics, Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute, Liverpool, NSW, Australia. Sankar.Arumugam@health.nsw.gov.au.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To compare the intrafraction prostate motion monitoring capabilities between intrafraction Cone Beam Computed Tomography (IF-CBCT) and SeedTracker-based real-time monitoring, and to optimize imaging doses in real-time monitoring using the IF-CBCT image acquisition method. Simulations of static and dynamic intrafraction prostate motions were conducted on a phantom using a robotic arm. The study utilized the XVI imaging system of the Elekta linear accelerator for IF-CBCT and SeedTracker-based monitoring during hypofractionation and Stereotactic Body Radiation Therapy (SBRT). The optimal imaging frequency for real-time monitoring was determined by calculating VMAT gantry traverse times. The effective dose resulting from IF-CBCT and SeedTracker-based monitoring approaches were compared. IF-CBCT showed static offsets as seed duplications and the offsets calculated using 'Seed' automatic image registration available XVI system depend on the initial position of the seeds in verification and localisation image sets. This dependency resulted in large differences (up to 4.9 mm) between actual and calculated position offsets. Dynamic offsets resulted in blurring or duplication of seeds in IF-CBCT images depending on the type of the dynamic motion. SeedTracker-based real-time monitoring successfully identified position deviation events as they occurred during treatment. For hypofractionation and SBRT treatments, IF-CBCT imaging resulted in an effective dose of 54.3 mSv and 13.6 mSv, respectively. Optimized imaging frequency for real-time monitoring led to a dose reduction of up to 86.2% and 97.2% for hypofractionation and SBRT regimens, respectively, compared to the IF-CBCT approach. SeedTracker real-time monitoring effectively identified target position deviations in real-time, surpassing the capabilities of the IF-CBCT approach. Moreover, the SeedTracker imaging approach significantly reduced imaging doses compared to IF-CBCT.

Indexed as

Dose Fractionation, RadiationParticle AcceleratorsProstatic NeoplasmsCone-Beam Computed TomographyHumansMalePhantoms, ImagingRadiotherapy DosageRadiotherapy Planning, Computer-AssistedDose optimizationImaging doseIntrafraction CBCTProstate SBRTReal-time monitoring

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked