Evidence map›Paper›PMID 39991747›Full record

ArticleIEEE transactions on medical robotics and bionics2024

Robot-Assisted Reduction of the Ankle Joint via Multi-Body 3D-2D Image Registration.

R C Vijayan, N M Sheth, J Wei, K Venkataraman, D Ghanem, B Shafiq, J H Siewerdsen, W Zbijewski, G Li, K Cleary and 1 more

Abstract read
In one paragraph

Article in IEEE transactions on medical robotics and bionics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

R C VijayanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
N M ShethDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
J WeiDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
K VenkataramanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
D GhanemDepartment of Orthopaedic Surgery, Johns Hopkins Medicine, Baltimore MD.
B ShafiqDepartment of Orthopaedic Surgery, Johns Hopkins Medicine, Baltimore MD.
J H SiewerdsenDepartment of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston TX.
W ZbijewskiDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
G LiChildren's National Hospital, Washington DC.
K ClearyChildren's National Hospital, Washington DC.
A UneriDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.

Funding

Image-guided, robot-assisted reduction of joint dislocation in orthopaedic surgeryR01EB031958 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI UNERI, ALI · 2021 to 2024
$2.6M
NIBIB NIH HHS R01 EB031958
6 · The paper itself

Abstract

Purpose: Robot-assisted orthopaedic joint reduction offers enhanced precision and control across multiple axes of motion, enabling precise realignment according to predefined plans. However, the high levels of forces encountered may induce unintended anatomical motion and flex mechanical components. To address this, this work presents an approach that uses 2D fluoroscopic imaging to verify and readjust the 3D reduction path by tracking deviations from the planned trajectory. Methods: The proposed method involves a 3D-2D registration algorithm using a pair of fluoroscopic images, along with prior models of each body in the radiographic scene. This objective is formulated to couple and constrain multiple object poses (fibula, tibia, talus, and robot end effector), and incorporate novel methods for automatic view and hyperparameter selection to improve robustness. The algorithms were refined through cadaver studies and evaluated in a preclinical trial, employing a robotic system to manipulate a dislocated fibula. Results: Studies with cadaveric specimens highlighted the joint-specific formulation's high registration accuracy ( Conclusions: The solution offers to close the loop on image-based guidance of robot-assisted joint reduction by tracking the robot and bones to dynamically correct the course. The approach uses standard clinical images and is expected to lower radiation exposure by providing 3D information and allowing the staff to stay clear of the x-ray beam.

Indexed as

3D-2D registrationankle fracturefracture fixationImage-guided surgeryintraoperative imagingrobotic surgery

Identifiers

PMID39991747
PMCPMC11845218

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.