ArticleInnovation (Cambridge (Mass.))2025
Self-calibrating multiplexed microneedle electrode array for continuous mapping of subcutaneous multi-analytes in diabetes.
Article in Innovation (Cambridge (Mass.)), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- In Vivo Continuous Biosensing: Design Considerations and Emerging Technologies.Small (Weinheim an der Bergstrasse, Germany) · 2026Review
- Smart wearable biosensors: a transformative synergy between diagnosis and treatment of disease.RSC advances · 2026Review
- Challenges of Wearable Biosensors and Ways to Overcome Them.Biosensors · 2026Review
- A programmable bioresorbable electrochemical microneedle sensor array for perioperative monitoring of organ health.Nature biomedical engineering · 2026Article
- Microneedle-Based Multiplexed Monitoring of Diabetes Biomarkers: Capabilities Beyond Glucose Toward Closed-Loop Theranostic Systems.ACS sensors · 2025Review
- Microneedles in biomedicine: Innovations, challenges, and future prospects.Biomaterials translational · 2025Review
Corrections and comments
- Erratum issued
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Monitoring multiplexed biochemical markers is beneficial for the comprehensive evaluation of diabetes-associated complications. Techniques for multiplexed analyses in interstitial fluids have often been restricted by the difficulties of electrode materials in accurately detecting chemicals in complex subcutaneous spaces. In particular, the signal stability of enzyme-based sensing electrodes often inevitably decreases due to enzyme degradation or interference
Indexed as
Identifiers
What OpenQuestion holds
Registered trials