Evidence map›Paper›PMID 39991268›Full record

ArticleTherapeutic advances in urology

Introducing a new device for direct in-scope suction technique during flexible ureteroscopy for kidney stone disease: an EAU Section of Endourology prospective multicenter audit using the GLITZ system.

Vineet Gauhar, Olivier Traxer, Nanjappa Madappa Kandarthanda, Bhaskar K Somani, Daniele Castellani, Ravindra B Sabnis, Deepak Ragoori

Abstract read
In one paragraph

Article in Therapeutic advances in urology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Vineet GauharDepartment of Urology, Ng Teng Fong General Hospital, Singapore, Singapore.
Olivier TraxerDepartment of Urology AP-HP, Sorbonne University, Tenon Hospital, Paris, France.
Nanjappa Madappa KandarthandaCauvery Uroderm Centre, Kalyan West, Kalyan, India.
Bhaskar K SomaniDepartment of Urology, University Hospitals Southampton, NHS Trust, Southampton, UK.ORCID https://orcid.org/0000-0002-6248-6478
Daniele CastellaniUrology Unit, Azienda Ospedaliero-Universitaria delle Marche, Via Conca 71, Ancona 60126, Italy.ORCID https://orcid.org/0000-0001-7354-9190
Ravindra B SabnisDepartment of Urology, Muljibhai Patel Urological Hospital, Nadiad, India.
Deepak RagooriDepartment of Urology, Asian Institute of Nephrology & Urology, Irram Manzil Colony, Hyderabad, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The direct in-scope suction (DISS) involves a two-way adaptor mounted on a scope to aspirate and irrigate the pelvicalyceal system during flexible ureteroscopy. While integrated suction single-use scopes manage small dust particles effectively, they cannot remove particles >250 µm and are limited by single use. Objectives: To evaluate perioperative outcomes of the GLITZ system, a lightweight suction accessory for flexible ureteroscopes, facilitating laser lithotripsy with integrated aspiration. Design: Prospective, multicenter study. Methods: The GLITZ system, a 100 g trigger mounted on the ureteroscope handle, integrates with an irrigation and aspiration apparatus featuring a flow-regulating sensor. A finger-trigger activates suction, stopping irrigation until released, enhancing visibility and safety by automatically stopping irrigation if blockages occur. The study involved 29 patients (November 2023-April 2024). Procedures were performed using a disposable 7.5 Fr ureteroscope, ureteral access sheath, and thulium fiber or 100 W holmium:YAG laser. Surgeons evaluated ease of use and performance. Stone-free status was evaluated at a 30-day CT scan and classified as follows: Grade A: zero RF; Grade B: single RF not up 2 mm; Grade C: single RF 2.1-4 mm; and Grade D: single/multiple RFs > 4 mm. Data are reported as median and (interquartile range). Results: A total of 31.1% of patients were female. The median age was 54 years. Pain was the most common complaint, and 41.8% had multiple stones. GLITZ system showed satisfactory performance in 93.1% of cases, with complete dust aspiration achieved in 62.1%. Device dislodgement occurred in 24.1% of cases. Median operative time was 40 min, achieving postoperative CT at 30 days confirmed Grade A stone-free status in 75.9%. Fever was the most common complication (10.3%), with no sepsis case. Conclusion: The GLITZ system in DISS shows effectiveness with a 96.6% stone-free rate (Grade A + B) at 30 days, indicating strong potential for flexible ureteroscopy, though additional studies are needed to optimize flow rates and usability.

Indexed as

direct-in-scope suctionflexible ureteroscopykidney stone disease

Identifiers

PMID39991268
PMCPMC11843708

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.