Geometric Calibration for a Next-Generation Digital Breast Tomosynthesis system Using Virtual Line Segments.

Chloe J Choi, Trevor L Vent, Raymond J Acciavatti, Andrew D A Maidment

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Development of a Next Generation Tomosynthesis System.Proceedings of SPIE--the International Society for Optical Engineering · 2018
    Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Chloe J ChoiUniversity of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia, PA 19104.
Trevor L VentUniversity of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia, PA 19104.
Raymond J AcciavattiUniversity of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia, PA 19104.
Andrew D A MaidmentUniversity of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia, PA 19104.

Funding

High Performance, Quantitative Breast PET Scanner Integrated With TomosynthesisR01CA196528 · NCI · UNIVERSITY OF PENNSYLVANIA · PI ANDREW DOUGLAS ARNOLD MAIDMENT, Suleman Surti · 2016 to 2026
$5.9M
SUMMER UNDERGRADUATE PROGRAM TO EDUCATE RADIATION SCIENTISTS (SUPERS)R25CA140116 · NCI · UNIVERSITY OF PENNSYLVANIA · PI JAY FITZGERALD DORSEY · 2010 to 2026
$4.1M
NCI NIH HHS R01 CA196528NCI NIH HHS R25 CA140116
6 · The paper itself

Abstract

Our next-generation tomosynthesis (NGT) system prototype introduces additional geometric movements to conventional Digital Breast Tomosynthesis (DBT) acquisition geometries, to provide isotropic super-resolution. These movements include x-ray source movement in the posteroanterior (PA) direction and detector movement in the z-direction (perpendicular to the breast support). The desired benefits of the NGT system are only achievable with precise geometric calibration. In our previous work, a geometric phantom with 24 point-like ball bearings (BB's) at four different magnifications was designed and a geometric calibration method that minimizes the difference between the projected locations and the calculated locations of BB's was tested. This study investigates a new calibration method using the same phantom, utilizing projected 2D equations of virtual line segments created by any two BB's for more precise reconstruction of the various acquisition modes of the NGT system. The geometric parameters were solved with two approaches: (1) solving each projection individually and (2) solving all projections simultaneously. Furthermore, two algorithms to compensate for any possible inaccuracy in BB locations within the phantom, presumably by less than desired manufacturing precision, were developed and compared: (1) manually identifying and removing poorly positioned BB's and (2) performing an iteration to re-calculate the BB locations. Magnification digital breast tomosynthesis was also performed to test the calibration method further. Tomographic image reconstructions successfully demonstrated isotropic super-resolution and magnified super-resolution.

Indexed as

calibration phantomDigital breast tomosynthesis (DBT)isotropic super-resolutionmagnification digital breast tomosynthesis (MDBT)mammographyx-ray imaging

Identifiers

PMID39991048
PMCPMC11845276

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.