Evidence map›Paper›PMID 39988479›Full record

ArticleOrthopaedic surgery2025

Biomechanical Effects of Zero-P Height on Anterior Cervical Discectomy and Fusion: A Finite Element Study.

Cheng-Yi Huang, Jun-Bo He, Xing-Jin Wang, Ting-Kui Wu, Bei-Yu Wang, Jin Xu, Hao Liu

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Cheng-Yi HuangDepartment of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China.ORCID https://orcid.org/0000-0001-8093-816X
Jun-Bo HeDepartment of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China.
Xing-Jin WangDepartment of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China.ORCID https://orcid.org/0000-0001-7309-0041
Ting-Kui WuDepartment of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China.
Bei-Yu WangDepartment of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China.ORCID https://orcid.org/0000-0001-8755-1427
Jin XuDepartment of Pain Treatment, Tianjin Hospital, Tianjin, China.
Hao LiuDepartment of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China.

Funding

the 1.3.5 project for Postdoctoral Foundation of West China Hospital of Sichuan University 2023HXBH080the Cadre Health Research Project of Sichuan Province ZH2023-105the National Natural Science Foundation of China 82302785
6 · The paper itself

Abstract

objectiveThe principle of selecting a Zero-P implant of an appropriate height remains a topic of debate, particularly when similarly sized implants seem to appropriately fit the intervertebral space. Thus, this study compared the biomechanical performance of smaller and larger Zero-P implants within an appropriate height range with that of oversized Zero-P implants for anterior cervical discectomy and fusion (ACDF).

methodsA three-dimensional finite element (FE) model of the C2-C7 cervical spine was constructed and validated. The implants were categorized as smaller (6 mm), larger (7 mm), and oversized (8 mm) according to the average intervertebral height and implant specifications. Thus, the following four FE models were constructed: the intact cervical spine model (M1), the 6 mm model (M2), the 7 mm model (M3), and the 8 mm (M4) Zero-P implant C5/6 segment ACDF surgical model. Then, a pure moment of 1.0 N·m combined with a follower load of 75 N was applied at C2 to simulate flexion, extension, lateral bending, and axial rotation.

resultsThe results indicated that the maximum stress on the vertebral body, intervertebral disc, and facet joints under self-weight increased with increasing Zero-P height. Under six different loading conditions, the maximum stress on the vertebral body in the surgical segment of the M4 model was generally greater than that in the M2 and M3 models. Following an increase in the height of the implant from 6 mm to 8 mm, the maximum stress increased, and the intervertebral disc stress of both segments reached its peak in the M4 model. In the M4 model, the implant experienced the highest stress, whereas the M2 model exhibited the lowest stress on the implant under both self-weight and loading conditions. Furthermore, the stress on the posterior facet joints of the surgical segment increased with increasing Zero-P height. The range of maximum stress on the posterior facet joints for the M3 model was situated between that of the M2 and M4 models.

conclusionIn summary, after determining the appropriate height range for the implant in accordance with the mean height of the intervertebral space, opting for a larger size appears to be more advantageous. This approach helps maintain the height of the intervertebral space and provides greater stress, promoting a tighter fit between the upper and lower endplates and the Zero-P. This tighter fit is crucial for maintaining spinal stability, enhancing the early bony fusion rate, and potentially leading to better postoperative outcomes.

Indexed as

Cervical VertebraeDiskectomyProstheses and ImplantsSpinal FusionBiomechanical PhenomenaFinite Element AnalysisHumansIntervertebral DiscProsthesis Designanterior cervical discectomy and fusionbiomechanicsfinite element analysiszero‐P

Identifiers

PMID39988479
PMCPMC11962274

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.