Evidence map›Paper›PMID 39987341›Full record

ReviewPediatric research2025

Electrical impedance tomography in neonates: a review.

Ako A Ako, Ahmed Ismaiel, Shantanu Rastogi

Abstract readReview
In one paragraph

Review in Pediatric research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Trial
  2. Article
  3. [Research on electrical impedance tomography for pediatric pneumonia based on an improved radial basis function neural network].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2026
    Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. The feasibility of using electrical impedance tomography to guide positive pressure airway clearance in children with cystic fibrosis and tracheobronchomalacia.Canadian journal of respiratory therapy : CJRT = Revue canadienne de la therapie respiratoire : RCTR · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Ako A Ako *Division of Neonatology, Children's Hospital at Montefiore, Albert Einstein College of Medicine, Bronx, New York, 10467, USA.
Ahmed Ismaiel *Division of Neonatology, Children's Hospital at Montefiore, Albert Einstein College of Medicine, Bronx, New York, 10467, USA.
Shantanu RastogiDivision of Neonatology, Children's Hospital at Montefiore, Albert Einstein College of Medicine, Bronx, New York, 10467, USA. shrastogi@montefiore.org.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Appropriate interventions informed by real-time assessment of pulmonary function in mechanically ventilated critically ill neonates can reduce the incidence of bronchopulmonary dysplasia, pneumothorax, intraventricular hemorrhage and other complications of newborn life. The respiratory system in neonates is uniquely different from older children, and its physiological and anatomic attributes increase neonatal vulnerability to respiratory distress and eventual failure. While significant advancements have been made in developing respiratory support for neonates, such support is accompanied by inherent risks to their delicate lungs. Ventilator-associated lung injury poses a critical concern that can be potentially decreased with more precise, non-invasive, non-radiating, bedside methods for assessing neonatal pulmonary function in real time. Electrical impedance tomography (EIT) is one such tool, with immense potential for real-time pulmonary function monitoring in neonates. Still relatively new and in the earliest stages of clinical adoption, EIT use in neonatal critical care has been reported in several studies. This review discusses the basic features of EIT, its distinct advantages over traditional pulmonary function monitoring tools, the scope of its adoption in neonatal clinical practice, challenges associated with clinical adoption, and prospects for future applications. IMPACT: 1. Individualized care assisted by bedside pulmonary function monitoring can positively impact neonatal critical care and outcomes. 2. Electrical impedance tomography (EIT) has the potential to improve neonatal pulmonary function monitoring and treatment outcomes. 3. Electrical impedance tomography can be adopted as a part of routine neonatal respiratory critical care, especially in the population of patients most at risk for bronchopulmonary dysplasia and acute respiratory complications.

Indexed as

Electric ImpedanceLungTomographyHumansInfant, NewbornMonitoring, PhysiologicRespiration, ArtificialRespiratory Function TestsVentilator-Induced Lung Injury

Identifiers

PMID39987341
PMCPMC12454141

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked