Evidence map›Paper›PMID 39987280›Full record

ArticleAnnals of biomedical engineering2025

Comparison of Instrumented Mouthguard Post-Processing Methods.

Ryan Gellner, Mark T Begonia, Matthew Wood, Lewis Rockwell, Taylor Geiman, Caitlyn Jung, Blake Gellner, Allison MacMartin, Sophia Manlapit, Steve Rowson

Abstract readComparative Study
In one paragraph

Article in Annals of biomedical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Ryan GellnerVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA. gryan3@vt.edu.ORCID http://orcid.org/0000-0001-7092-2527
Mark T BegoniaVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.
Matthew WoodVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.
Lewis RockwellVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.
Taylor GeimanVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.
Caitlyn JungVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.
Blake GellnerVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.
Allison MacMartinVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.
Sophia ManlapitVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.
Steve RowsonVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Instrumented head acceleration measurement devices are commonly used in research studies to determine head acceleration exposure in certain populations. Instrumented mouthguards pair directly to the user's teeth and offer six-degree-of-freedom measurements. Though many studies have recently used these devices, post-processing techniques vary by study. Other studies have attempted to label impact quality or coupling status, also with varying methods. This study sought to compare the effect of post-processing and labeling methods on reported exposure distribution characteristics in instrumented mouthguard data from ice hockey players. We collected data from 18 female adolescent ice hockey players on two teams for an entire season. We then post-processed the measured signals using five different techniques: (1) the instrumented mouthguard manufacturer's data output, (2) a 500 Hz linear acceleration filter and a 300 Hz angular velocity filter, (3) HEADSport, (4) a 100 Hz linear acceleration filter and a 175 Hz angular velocity filter, and (5) a salvaging process to detect and remove decoupling based on signal frequency content. The post-processing techniques affected the reported exposure distributions by changing the mean, median, and 95th percentile values of peak linear and angular kinematics. We also compared labeling techniques by measuring agreement and inter-rater reliability between three labeling techniques: the instrumented mouthguard manufacturer's label, Luke et al.'s coupling label, and our classification learner that detects and labels decoupling. We found that the labeling techniques had low agreement about which acceleration events were the best to keep. Labeling technique also influenced the reported distributions' descriptive statistics. Post-processing and event labeling are crucial components of head acceleration event exposure studies. Methods should be described by researchers, and standardization should be sought to allow for better cross-study comparison. Published and publicly available techniques can help move the field toward this ideal. Researchers should be aware of the potential effect post-processing can have on a population's final reported exposure metrics.

Indexed as

AccelerationHeadHockeyMouth ProtectorsAdolescentFemaleHumansArtifactHead impactInstrumented mouthguardLabelingPost-processingSalvage

Identifiers

PMID39987280
PMCPMC12006221

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.