Evidence map›Paper›PMID 39985252›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2025

Anti-Motion Artifacts Iontronic Sensor for Long-Term Accurate Fingertip Pulse Monitoring.

Jia You, Mingyang Lu, Lamu Dazhen, Mengjie Gao, Ruiyan Zhang, Wendong Li, Fan Lei, Wei Ren, Guangxian Li, Junlong Yang

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Wearable Flexible Sensors for Cardiovascular Disease Monitoring.Advanced materials (Deerfield Beach, Fla.) · 2026
    Review
  2. Highly Aligned Bacteria Cellulose Yarn Aggregation for Energy Generation and Strain Sensing.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  3. Ionic-Bionic Interfaces: Advancing Iontronic Strategies for Bioelectronic Sensing and Therapy.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  4. Article
  5. Review
  6. Article
  7. Anti-Motion Artifacts Iontronic Sensor for Long-Term Accurate Fingertip Pulse Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jia YouCollege of Polymer Science and Engineering, National Key Laboratory of Advanced Polymer Materials, Sichuan University, Chengdu, Sichuan, 610065, China.
Mingyang LuCollege of Polymer Science and Engineering, National Key Laboratory of Advanced Polymer Materials, Sichuan University, Chengdu, Sichuan, 610065, China.
Lamu DazhenCollege of Polymer Science and Engineering, National Key Laboratory of Advanced Polymer Materials, Sichuan University, Chengdu, Sichuan, 610065, China.
Mengjie GaoCollege of Polymer Science and Engineering, National Key Laboratory of Advanced Polymer Materials, Sichuan University, Chengdu, Sichuan, 610065, China.
Ruiyan ZhangKey Laboratory of Photovoltaic Materials, School of Materials and New Energy, Ningxia University, Yinchuan, Ningxia, 750021, China.
Wendong LiSchool of Aeronautics and Astronautics, State Key Laboratory of Polymer Materials Engineering of China, Robotic Satellite Key Laboratory of Sichuan Province, Sichuan University, Chengdu, Sichuan, 610065, China.
Fan LeiSchool of Mechanical Engineering, Chengdu University, Chengdu, Sichuan, 610106, China.
Wei RenCollege of Polymer Science and Engineering, National Key Laboratory of Advanced Polymer Materials, Sichuan University, Chengdu, Sichuan, 610065, China.
Guangxian LiCollege of Polymer Science and Engineering, National Key Laboratory of Advanced Polymer Materials, Sichuan University, Chengdu, Sichuan, 610065, China.
Junlong YangCollege of Polymer Science and Engineering, National Key Laboratory of Advanced Polymer Materials, Sichuan University, Chengdu, Sichuan, 610065, China.ORCID https://orcid.org/0009-0004-5997-224X

Funding

National Key R&D Program of China 2023YFB3813404National Natural Science Foundation of China 51903118National Natural Science Foundation of China 52403084National Natural Science Foundation of China U2330118Sichuan Science and Technology Program 2024NSFSC1027State Key Laboratory of Polymer Materials Engineering sklpme2020-1-07
6 · The paper itself

Abstract

Flexible pressure sensors have gained attention for their comfort, portability, and potential in long-term pulse monitoring and early cardiovascular disease diagnosis. However, stretching stress during daily activities affects sensor accuracy, causing motion artifacts (MAs) that hinder precise pulse signal detection. To address this challenge, the anti-motion artifact iontronic pressure sensor (S-smooth sensor), featuring a soft-hard stretchable interface with energy dissipation properties is developed. By regulating the local modulus of the encapsulation layer, this structure dissipates stretching stress, achieving an MAs suppression rate of up to 90%, significantly improving pulse signal accuracy and reliability. Additionally, the sensor incorporates a dielectric layer and double electrode layer (EDL) sensing interface, with a low-friction design that ensures high sensitivity (92.76 kPa-¹) and stability, maintaining performance over millions of cycles. The sensor accurately captures heart rate (HR) and pulse peak time differences (Δt) under various finger-bending conditions. When integrated into a portable wireless pulse monitoring system, it shows a heart rate loss rate of only 2.9% during intense physical activity. This approach avoids complex chemical processes and material restrictions, offering a novel solution for motion artifact suppression in sensors, with significant potential for real-time health monitoring and assisted diagnosis.

Indexed as

ArtifactsFingersHeart RateEquipment DesignHumansMonitoring, PhysiologicMotionPulseReproducibility of ResultsWearable Electronic Devicesanti‐motion artifactsfingertip pulse monitoringlong‐term stabilitysoft‐hard stretchable interfaceS‐smooth sensor

Identifiers

PMID39985252
PMCPMC12005763

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.