Evidence map›Paper›PMID 39984810›Full record

ArticleJournal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology2025

Higher nonunion rates with locking plates compared to dynamic compression plates in forearm diaphyseal fractures: a multicenter study.

Tzu-Hao Tseng, Chih-Chien Hung, Hung-Kuan Yen, Ho-Min Chen, Chen-Yu Wang, Shi-Chien Tzeng, Shau-Huai Fu

Abstract readMulticenter StudyComparative Study
In one paragraph

Article in Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Tzu-Hao TsengDepartment of Orthopedic Surgery, National Taiwan University Hospital, No.7 Chungsan South Road, Taipei, 10002, Taiwan.
Chih-Chien HungDepartment of Orthopedics, National Taiwan University Hospital Yun-Lin Branch, No.579, Sec. 2, Yunlin Rd., Yunlin County 632, Douliu, Taiwan.
Hung-Kuan YenDepartment of Orthopedic Surgery, National Taiwan University Hospital, No.7 Chungsan South Road, Taipei, 10002, Taiwan.
Ho-Min ChenHealth Data Research Center, National Taiwan University, Taipei, Taiwan.
Chen-Yu WangNational Center for Geriatrics and Welfare Research, National Health Research Institutes, Zhunan, Taiwan.
Shi-Chien Tzeng *Department of Orthopedic Surgery, National Taiwan University Hospital, No.7 Chungsan South Road, Taipei, 10002, Taiwan. irene.lover@gmail.com.
Shau-Huai Fu *Department of Orthopedic Surgery, National Taiwan University Hospital, No.7 Chungsan South Road, Taipei, 10002, Taiwan. b90401045@gmail.com.ORCID http://orcid.org/0000-0001-9853-872X

Funding

National Science and Technology Council NSTC 111-2314-B-002-103-MY2National Taiwan University Hospital Yunlin Branch NTUHYL112-F009National Taiwan University Hospital Yunlin Branch NTUHYL112-X021
6 · The paper itself

Abstract

backgroundDynamic compression plate (DCP) osteosynthesis is the gold standard for treating forearm diaphyseal fractures, providing stability and promoting healing. Locking plates (LPs) are increasingly used in modern fracture management but may increase the risk of nonunion if applied with excessive rigidity and without proper fracture site compression. The purpose of this study is to compare the nonunion rate between LPs and DCPs. MATERIALS AND

methodsWe conducted a retrospective study by reviewing the medical records and radiographs of 515 patients diagnosed with radial and/or ulnar shaft fractures at three trauma centers between 2014 and 2019. Inclusion criteria were patients treated with locking plates (LPs), locking compression plates (LCPs), or dynamic compression plates (DCPs) who had at least 9 months of outpatient follow-up and imaging assessments. Exclusion criteria included treatment with other methods, hospitalization for pathological fractures or implant removal, or incomplete surgical records. Data on patient demographics, injury details, and surgical outcomes were collected to compare nonunion rates, as well as early and late complications, between the LP and DCP groups.

resultsA total of 368 patients were included in the analysis. Among them, 132 (35.9%) had isolated radial shaft fractures, 116 (31.5%) had isolated ulnar shaft fractures, and 120 (32.6%) had both-bone fractures. Of these, 124 patients received LP implants, 98 were treated with LCPs, and 146 were treated with DCPs. Early complications were comparable among the groups; however, the nonunion rate was significantly higher in the LP group (18.5% versus 11.2% versus 6.2%, p < 0.007). Logistic regression identified LP use [odds ratio (OR): 3.05, 95% confidence interval (CI) 1.24-7.53] as a significant predictor of nonunion. Notably, LPs lacking dynamic compression functionality were associated with markedly higher odds of nonunion in radial shaft fractures (OR: 26.94, 95% CI 3.52-206.15). These findings collectively indicate that LPs increase the nonunion rate in forearm fractures.

conclusionsUsing LPs without compression functionality to treat forearm diaphyseal fractures increases the nonunion rate, particularly in radial shaft fractures. Therefore, we recommend using LCPs or DCPs for forearm diaphyseal fractures to ensure adequate compression at the fracture site during fixation, thereby promoting optimal bone healing rates. LEVEL OF EVIDENCE: Level III: retrospective comparative therapeutic study.

Indexed as

Bone PlatesFracture Fixation, InternalFractures, UnunitedRadius FracturesUlna FracturesAdultAgedDiaphysesFemaleFracture HealingHumansMaleMiddle AgedRetrospective StudiesDynamic compression plateForearm diaphyseal fractureFractures of the radius of the forearmFractures of the ulna of the forearmLocking plateNonunion

Identifiers

PMID39984810
PMCPMC11845636

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.