ArticleScientific reports2025
Cascaded Fabry-Perot interferometer with thin film based on Vernier effect.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Band-bending engineering in CuChemical science · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The Vernier effect is often utilized to boost the sensing ability of optical fiber sensors. In this paper, theoretical model of cascaded Fabry-Perot interferometer (FPI) with thin film based on Vernier effect is established. The sensitivities of the envelope spectra, thin film cavity and mixed cavity of air-thin film are analyzed qualitatively. According to the theoretical analysis, although sensitivity from mixed cavity of air-thin film is amplified, the value is equal to the sensitivity of sing thin film cavity. Experimental verification is carried out by an example of thin film named polydimethylsiloxane (PDMS) polymer. Herein, a new FPI constructed by air cavity from a hollow-core fiber, PDMS cavity, and air-PDMS mixed cavity is proposed and demonstrated. In order to facilitate the generation of the Vernier effect, the length of the PDMS cavity is intentionally designed shorter than the air cavity, making the free spectral range of the air-PDMS cavity and air cavity is approximately equal. The temperature change makes the refractive index and thermal expansion of PDMS change, while gas pressure change results in elastic deformation of PDMS. The Vernier envelope wavelength shifts with the temperature and gas pressure change. The proposed FPI features high temperature and gas pressure sensitivities of 3.07 nm/℃, and 23.07 nm/MPa, and a high magnification factor of 17 when the lengths of HCF and PDMS are 82.5 and 3.7 μm, respectively. The experimental results show that the temperature and pressure sensitivities of the cascaded FPI's envelope spectra are equal to the sensitivity of a single thin film microcavity, and the theoretical calculation is in good agreement with the experimental verification. The theoretical model is also applicable to thin film prepared by other polymer materials. Additionally, the proposed FPI has good stability, reversibility, and repeatability, which is a good choice in the field of optical fiber sensing.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.