Evidence map›Paper›PMID 39975634›Full record

ArticleNanophotonics (Berlin, Germany)2025

Localizing axial dense emitters based on single-helix point spread function and compressed sensing.

Hanzhe Wu, Danni Chen, Yihong Ji, Gan Xiang, Yanxiang Ni, Heng Li, Bin Yu, Junle Qu

Abstract read
In one paragraph

Article in Nanophotonics (Berlin, Germany), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hanzhe WuKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, Guangdong Province, China.ORCID https://orcid.org/0009-0001-0318-9414
Danni ChenKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, Guangdong Province, China.
Yihong JiKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, Guangdong Province, China.
Gan XiangKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, Guangdong Province, China.
Yanxiang NiKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, Guangdong Province, China.ORCID https://orcid.org/0000-0002-0467-9722
Heng LiTsinghua-Berkeley Shenzhen Institute (TBSI), Tsinghua University, Shenzhen, 518055, China.ORCID https://orcid.org/0000-0002-2196-6520
Bin YuKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, Guangdong Province, China.ORCID https://orcid.org/0000-0002-8698-0155
Junle QuKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, Guangdong Province, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Among the approaches in three-dimensional (3D) single molecule localization microscopy, there are several point spread function (PSF) engineering approaches, in which depth information of molecules is encoded in 2D images. Usually, the molecules are excited sparsely in each raw image. The consequence is that the temporal resolution has to be sacrificed. In order to improve temporal resolution and ensure localization accuracy, we propose a method, SH-CS, based on light needle excitation, detection system with single helix-point spread function (SH-PSF), and compressed sensing (CS). Although the SH-CS method still has a limitation about the molecule density, it is suited for relatively dense molecules. For each light needle scanning position, an SH image of excited molecules is processed with CS algorithm to decode their axial information. Simulations demonstrated, for random distributed 1-15 molecules in depth range of 4 μm, the axial localization accuracy is 12.1-73.5 nm. The feasibility of this method is validated with a designed 3D sample composed of fluorescent beads.

Indexed as

compressed sensingsingle-helix point spread functionthree-dimensional single molecule localization microscopy

Identifiers

PMID39975634
PMCPMC11834055

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.