Evidence map›Paper›PMID 39975521›Full record

ArticleJournal of biomedical physics & engineering2025

Evaluation of Interfractional Setup Uncertainties and Calculation of Adequate CTV-PTV Margin for Head and Neck Radiotherapy using Electronic Portal Imaging Device.

Elham Ahmadi, Azam Eskandari, Mohammad Mohammadi, Maryam Naji, Shahrokh Naseri, Hamid Gholamhosseinian

Abstract read
In one paragraph

Article in Journal of biomedical physics & engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Elham AhmadiDepartment of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
Azam EskandariDepartment of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
Mohammad MohammadiRoyal Adelaide Hospital, Department of Medical Physics, Adelaide, Australia.
Maryam NajiDepartment of Radiation Oncology, Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran.
Shahrokh NaseriDepartment of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
Hamid GholamhosseinianDepartment of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The evaluation of treatment-associated errors is important in the radiotherapy process, particularly those resulting related to patient setup. Objective: This research aimed to assess the interfractional setup errors and determine the Clinical Target Volume to Planning Target Volume (CTV to PTV) margin in patients undergoing 3-Dimensional Conformal Radiation Therapy (3DCRT) for head and neck cancer by means of electronic portal imaging device. Material and Methods: In this analytical study, 300 portal images were acquired from 50 patients undergoing 3DCRT for head and neck cancer. Using the portal images of Lateral (LAT) and Antero-Posterior (AP) fields, population systematic (∑) and random (σ) errors were obtained in the lateral, longitudinal, and vertical directions. Finally, based on the International Commission on Radiation Units and Measurements (ICRU) Report 62's, Stroom's and Van Herk's methods, Planning target volume margins were determined. Results: The translational shift ranges were 0-8.1 mm in the ML, 0-9 mm in the SI (AP), 0-8.8 mm in the SI (LAT), and 0-10 mm in the AP directions. The population systematic and random errors were respectively 3.230, 2.753, and 2.997 mm, and 1.476, 1.853, and 1.715 mm in X, Y, and Z directions. The calculated PTV margins using the ICRU-62, Stroom's, and Van Herk's formulae were ranging from 3.236-3.551, 6.605-7.493, and 7.932-9.108 mm, respectively. Conclusion: A PTV margin of 7.5-9.5 mm seems safe for ensuring adequate treatment volume coverage. In addition, the EPID is an effective equipment for verifying patient positioning and reducing treatment setup errors.

Indexed as

Head and Neck CancerPatient PositioningRadiotherapySetup ErrorsSystematic Error

Identifiers

PMID39975521
PMCPMC11833158

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.